COMPRESSORI - ASPIRATORI A CANALE LATERALE ‘SCL K-TD MOR’
ISTRUZIONI I
LATERAL CHANNEL BLOWERS - EXHAUSTERS ‘SCL K-TD MOR’
INSTRUCTIONS GB
COMPRESSEURS - ASPIRATEURS A CANAL LATERAL ‘SCL K-TD MOR’
INSTRUCTIONS F
SEITENKANALVERDICHTER - VAKUUMPUMPEN BAUREIHE ‘SCL K-TD MOR’
BETRIEBSANLEITUNG D
COMPRESORES - ASPIRADORES DE CANAL LATERAL ‘SCL K-TD MOR’
INSTRUCCIONES E
LEGGERE ATTENTAMENTE TUTTE LE ISTRUZIONI E CONSERVARLE I
PLEASE READ CAREFULLY ALL INSTRUCTIONS AND KEEP THEM FOR FUTURE REFERENCE GB
LIRE ATTENTIVEMENT TOUTES LES INSTRUCTIONS ET LES CONSERVER F
ALLE ANLEITUNGEN SIND SORGFÄLTIG ZU LESEN UND AUFZUBEWAHREN! D
SIRVASE LEER CUIDADOSAMENTE TODAS LAS INSTRUCCIONES Y CONSERVARLAS PARA FUTURA REFERENCIA E
SN 1977-0
®
F.P.Z. effepizeta s.r.l.
Via F.lli Cervi 16/18
20049 Concorezzo - (MI) - ITALIA
Tel. +39 039 604 1820
Fax +39 039 604 1296
www.fpz.com
SCL K07 / K08 / K09 / K10 / K11

Table of Contents

Questions and Answers

  • R
    Ronald RichardsonAug 8, 2025
    What to do if my FPZ Blower unit does not start?
    • L
      Linda DuffyAug 8, 2025
      If your FPZ Blower doesn't start, there are several potential causes: * Incorrect electric wiring: Check the electric wiring against the wiring diagram located in the terminal board box. * Unsuitable power supply voltage: Ensure that the power supply voltage, measured at the motor’s terminals, is within ± 5% of the nominal voltage. * Stuck impeller: In this case, it is best to get trained personnel to repair the machine.
  • H
    heather64Aug 12, 2025
    Why does the power absorption of my FPZ SCL K11-TD exceed the maximum allowed?
    • C
      Chad FergusonAug 12, 2025
      If the power absorption of your FPZ Blower exceeds the maximum allowed, consider the following: * Incorrect wiring: Verify the electric wiring against the wiring diagram in the terminal board box. * Voltage drop on the power supply: Restore the power supply voltage at the terminals to within the allowed values. * Clogged intake filter: Clean or replace the cartridge. * Deposits inside the unit: Have trained personnel clean the machine internally. * Operating beyond allowed pressure/vacuum: Adjust the plant and/or the regulating valve to reduce the pressure differentials.
  • V
    Victor WangAug 17, 2025
    How to reduce excessive noise from my FPZ SCL K11-TD Blower?
    • H
      Heather EdwardsAug 17, 2025
      Excessive noise in your FPZ Blower can stem from several issues: * Damaged soundproofing fabric: Replace the soundproofing fabric. * Impeller scraping against the chassis due to: * Operating at excessive pressure/vacuum: Adjust the plant to reduce pressure differentials. * Internal deposits: Have trained personnel clean the machine internally. * Worn bearing: Replace the bearing. * Unsuitable installation position: Install the units on structures that cannot transmit or amplify the noise.
  • S
    sally81Aug 22, 2025
    Why is the delivery air temperature high in my FPZ SCL K11-TD?
    • Y
      yduffyAug 22, 2025
      High delivery air temperature in your FPZ Blower can be due to: * Operating at excessive pressure/vacuum: Adjust the plant and/or regulating valve to reduce pressure differentials. * Clogged intake filter: Clean or replace the cartridge. * Internal deposits: Have trained personnel clean the machine internally. * Clogged intake/delivery piping: Remove the obstructions. * High intake air temperature: Use a heat exchanger to reduce the air temperature at the intake if it exceeds 40°C.
  • D
    Dr. Jennifer GomezAug 27, 2025
    What to do if the air flow rate is zero or insufficient in my FPZ SCL K11-TD Blower?
    • B
      Brandon SheltonAug 27, 2025
      If your FPZ Blower has zero or insufficient airflow, check the following: * Incorrect rotation direction: Ensure the direction of rotation matches the indication on the motor’s fan cowling. * Clogged intake filter: Clean or replace the cartridge.
  • J
    jennifer14Sep 2, 2025
    Why is my FPZ SCL K11-TD Blower experiencing abnormal vibrations?
    • J
      Jeffrey ThomasSep 2, 2025
      Abnormal vibrations in your FPZ Blower may be caused by: * Damaged impeller: Replace the impeller. * Deposits on the impeller: Get trained personnel to clean the machine internally. * Incorrect unit fixing: Fix the unit on anti-vibration supports.

Summary

Declaration of Conformity

Unit Conformity with Directives

Details compliance with Machinery, EMC, and Low Voltage directives.

Functional Testing

States the unit passed functional testing and meets requirements.

General Instructions

Conditions of Use

Defines the operational environment, limitations, and required filters for safe use.

Storage and Shipping

Provides guidelines for proper storage and safe transportation of the unit.

Installation

Outlines general installation requirements, environmental considerations, and precautions.

Electric Motor

Details about the electric motor selection, connection, and operation.

Commissioning

Steps to put the unit into operation and verify its performance.

Operating Adjustments

How to adjust and control the unit's performance and pressure.

Maintenance

Procedures for cleaning, inspection, and upkeep of the unit.

Installation Sketches

Pressure Service

Diagram illustrating installation for pressure applications.

Vacuum Service

Diagram illustrating installation for vacuum applications.

Parallel Pressure Service

Diagram for parallel configuration in pressure mode.

Parallel Vacuum Service

Diagram for parallel configuration in vacuum mode.

List of Accessories

Enumeration of available optional accessories.

Set Up Instructions

Start-Up with 90° Manifold

Steps for initial operation when using a 90° manifold.

Start-Up Without 90° Manifold

Steps for initial operation without the 90° manifold.

Internal Cleaning Instructions

Cleaning Instructions for SCL K07-TD; K08-TD

Specific steps for cleaning models K07-TD and K08-TD.

Cleaning Instructions for SCL K09-TD; K10-TD; K11-TD

Specific steps for cleaning models K09-TD, K10-TD, and K11-TD.

Replacement Sound-Absorbing Panels

FPZ SCL K11-TD Specifications

General IconGeneral
BrandFPZ
ModelSCL K11-TD
CategoryBlower
LanguageEnglish