13. SAFETY FEATURES
14. CARE AND MAINTENANCE
COMPRESSOR PROTECTION
Its duration is 3 minutes after the unit has been shut down; within this period, the unit cannot be restarted.
WARNING!
Before cleaning or maintenance, make sure to disconnect the unit’s power cable.
AUTOMATIC DEFROSTING
In case the unit operates in the heating mode, ice may form at the evaporator. In such case, the unit stops operation to melt ice and is restarted later.
1. Air lter cleaning
The air lter has to be inspected at least once every two weeks of operation. Operating the unit with contaminated or blocked air lters reduces its
performance and may cause serious problems. To remove the lter, take the back grate off and pull it gently.
Use a vacuum cleaner to remove dust. If it is not sufcient, wash the lter using slightly warm water with neutral detergent (if necessary), rinse it with
cold water, and leave it until it dries before reinstalling. Once the lter is reinstalled in its place, put the grate back on and restart the unit.
2. Housing cleaning
Use soft, dampened cloth to clean the outer surfaces of the air conditioner. Do not use hot water, solvents, petrol or any aggressive chemicals, talcum
powder or brushes: such agents may damage the surface or discolour it. Any stains should be removed using warm water with a drop of neutral de-
tergent. Do not drain the water tank for cleaning: it may damage its internal components or cause a short circuit.
Issue / Error Cause Solution
FL Water tank full Drain the tank. If the error persists, contact authorised repair service.
E1 Indoor temperature sensor failure. Contact authorised repair service.
E2 Evaporator temperature sensor failure. Contact authorised repair service.
The unit won’t start
No power. Connect the cable to an electrical socket and turn the unit on.
Water tank full: FL error. Drain the tank.
Timer is active. Reset timer.
Indoor temperature is too low or too high. Use only in the range of 7°C to 35°C.
The unit starts, but is
inactive
The unit is exposed to excessive sunlight. Draw the curtains.
The windows are open. Too many people in the
room or too many devices generate heat.
Close the windows.
The lter is very contaminated. Clean or replace the lter.
The air inlet is obstructed. Remove all possible obstructions.
Indoor temperature is lower than set tempera-
ture.
Change the temperature setting.
The unit operates
noisily
The unit has not been placed on level ground. Place the unit on rm and level ground.
The compressor
won’t start
The overheating protection has activated.
Check ventilation. Restart the unit in 5 minutes once the compressor
cools down.
The remote is not
operational
The remote is too far away from the air con-
ditioner.
Move the remote closer to the unit.
The control panel has not sensed the remote
signal.
Batteries are down. Replace the batteries.
12. POSSIBLE ISSUES
Do not repair the unit by yourself. Any unauthorised repair may void the warranty
FRAL SUPER COOL FSC12H