Power supply
cord Wiring requirements
115-volt (103.5 min. - 126.5 max.)
0-12 amps
15-amp time-delay fuse or circuit breaker
Use on single outlet circuit only.
230-volt (207 min. - 253 max.)
0-12 amps
15-amp time-delay fuse or circuit breaker
Use on single outlet circuit only.
¹⁄₄"
(0.6 cm)
The wall opening measurements should be:
Height (A): 17 ¼" plus twice thickness of wood used to build
frame
Width (B): 26 ¼"
Depth (D): 4" minimum to 8" maximum.
Electrical Requirements
Ground wire must be connected to ground screw located in lower
right corner of air conditioner when air conditioner is in cabinet.
The electrical ratings for your air conditioner are listed on the
model and serial number (nameplate) label. The model and serial
number label is located behind the front panel on the flange below
the control panel area.
Specific electrical requirements are listed in the chart below.
Follow the requirements for the type of plug on the power supply
cord.
Window installation
Window opening measurements:
27"min. to 42" max. (76.2 cm to 101.6 cm) opening width (A).
20" min. (50.8 cm) opening height (B).
Through-the-wall installation
A.27" min. (76.2cm)
B . 20" min. (50.8 cm)
A
B
A. 17 ¼"
B. 26 ¼"
C. Wood thickness
D. 4" minimum to
8" maximum.
CP15
CP18 / CP24
4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Friedrich CP15F10A and is the answer not in the manual?

Friedrich CP15F10A Specifications

General IconGeneral
BrandFriedrich
ModelCP15F10A
CategoryAir Conditioner
LanguageEnglish

Related product manuals