EasyManua.ls Logo

Friedrich UNI-FIT US08B10A - 1.3.2 SPECIFICATIONS FOR US10 B30 A;US12 B30 A (230 V)

Friedrich UNI-FIT US08B10A
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
—4—
1.3.2 FOR US10B30A-A/US12B30A-A
REMARK
POWER SUPPLY
COOLING CAPACITY (Btu/h)
INPUT (W)
RUNNING CURRENT
(A)
E.E.R. (Btu/W.h)
INDOOR (°C)
OUTDOOR (°C)
REFRIGERANT (R-22) CHARGE(g)
EVAPORATOR
CONDENSER
FAN, INDOOR
FAN, OUTDOOR
FAN SPEEDS (FAN/COOLING/HEATING)
FAN MOTOR
OPERATION CONTROL
ROOM TEMP. CONTROL
CONSTRUCTION
COMPRESSOR
FAN MOTOR
DRAIN SYSTEM
NET WEIGHT (lbs/kg)
DIMENSION (inch)
(W x H x D) (mm)
SLEEVE DIMESION (inch)
(W x H x D) (mm)
SLEEVE DEPTH (inch)
WITH FRONT GRILLE (mm)
1Ø, 230/208V, 60Hz
10,000/9,800 11,700/11,400
1,060/1,040 1,250/1,210
4.7/5.2 5.8/6.2
9.4/9.4 9.4/9.4
490g(17.3OZ) 475g(16.8OZ)
26.7(DB) 19.4(WB)
35(DB) 23.9(WB)
2 ROW 12STACKS 3 ROW 12STACKS
2ROW 17STACKS, L-BENDING TYPE
TURBO FAN
PROPELLER TYPE FAN WITH SLINGER-RING
3/3
6 POLES 4POLES
ELECTRIC
THERMISTOR
VERTICAL LOUVER(RIGHT & LEFT)
HORIZONTAL LOUVER(UP & DOWN)
TOP-DOWN
EXTERNAL OVERLOAD PROTECTOR
INTERNAL THERMAL PROTECTOR
1.4m (3WIRES WITH GROUNDING)
ATTACHMENT PLUG(CORD-CONNECTED TYPE, LCDI)
SPLASHED BY FAN SLINGER
78/35 80/36
24 x 14
13
/
32 x 20
3
/
32
610 x 366 x 499
25
7
/
8
x 15
17
/
32
x 16
23
/
32
656 x 394 x 425
20
1
/
2
521
MODELS
ITEMS
OPERATING
TEMPERA-TURE
AIR DIRECTION CONTROL
POWER CORD
PROTECTOR
LOUVERED-FIN TYPE
US10B30A-A US12B30A-A
OPTIONAL
PART

Related product manuals