EasyManua.ls Logo

Frient Entry Sensor Pro - User Manual

Frient Entry Sensor Pro
10 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
ba
<5mm
Frame
Window/
Door
a.
b.
c.
d.
e.
f.
3. Release the button while the LED is ashing
numerous times in a row.
4. After you release the button, the LED shows
one long ash, and the reset is completed.
eng
Modes
ACTIVATION MODE
A single green ash means that the sensor
and the magnet are moving either away from
or towards each other.
SEARCHING GATEWAY MODE
Red ashes every second for a longer period,
means that the device is searching for a gate-
way.
LOST CONNECTION MODE
When the red LED ashes 3 times, it means
that the device has failed to connect to a
gateway.
LOW-BATTERY MODE
Two consecutive red LED ashes every 60
seconds, means that the battery should be
replaced.
There are many ways to mount the sensor
and magnet, as windows and doors vary
greatly. The most important consideration
is for the magnet to be placed as near to
the point on the sensor indicated by the
grey arrow.
The sensor and magnet may be placed on
separate three dimensional planes, though
this does aect the maximum distance
allowed. The magnet may also be placed
either facing the side of the sensor or sitting
parallel to it.
Other information
Note local regulations about information to
your insurance company regarding installed
entry sensors.
Resetting
Resetting is needed if you want to connect
your entry sensor to another gateway or if you
need to perform a factory reset to eliminate
abnormal behavior.
STEPS FOR RESETTING
1. Press and hold down the reset button for
approximately 14-16 seconds.
2. While you are holding the button down, the
LED rst ashes once, then two times in a
row, and nally numerous times in a row.
Mounting
Clean the surface before mounting.
The entry sensor (a) should be mounted
to the frame using the double stick tape,
already applied on the back of the sensor
and magnet. Press rmly to secure sensor.
Testing
You can test if the positioning of the sensor
and magnet are correct by checking whether
the green light on the entry sensor is ashing
when you open or close the window/door.
Placement
Place the sensor indoors at a temperature
between 0-50°C.
The magnet has to be placed on that side
of the sensor which is marked with a small
triangle.
The magnet and sensor also have to be
aligned/centered thickness-wise on as
similar level as possible.
In case of a weak or a bad signal, change the
location of the entry sensor or strengthen
the signal with a smart plug.
SEE PAGE 2 FOR ILLUSTRATIONS
When removing cover for battery change -
electrostatic discharge can harm electronic
components inside.
Always mount indoors as the sensor is not
waterproof.
Do not place the sensor close to magnetic
or electromagnetic elds. This device
includes a magnet. The magnet creates
a magnetic eld that may cause damage
to computer hard drives, magnetic cards,
data storage devices, hearing aids and
speakers e.g. Therefore, we strongly advise
you to never position the magnet close to
electronic devices.
Getting started
1. Open the casing of the device by pushing
the fastening on top of the device to
remove the front panel from the back cover.
Product description
The entry sensor detects and reports opening
and closing of doors and windows. Easily
installed on any door or window, the sensor
triggers a signal when parted. This lets you
know when a room is entered, if a window or a
door has been left open, etc.
Entry Sensor/Pro
Fault nding
If the entry sensor does not work when the
window or door is parted, the probable
cause is a faulty battery. Replace the
batteries if they are worn out.
In case of a bad or weak signal, change the
location of the entry sensor. Otherwise you
can relocate your gateway or strengthen
the signal with a smart plug.
If the search for a gateway has timed out, a
short press on the button will restart it.
Battery replacement
CAUTION: RISK OF EXPLOSION IF BATTERIES
ARE REPLACED BY AN INCORRECT
TYPE. DISPOSE OF THE BATTERIES IN
ACCORDANCE WITH INSTRUCTIONS.
2. Insert the enclosed batteries into the
device, respecting the polarities
3. Close the casing
4. The entry sensor will now start searching
(up to 15 minutes) for a Zigbee network to
join.
5. Make sure that the Zigbee network is open
for joining devices and will accept the entry
sensor.
6. While the entry sensor is searching for
a Zigbee network to join, the red LED is
ashing.
Disposal
Dispose the product and battery properly at
the end of life. This is electronic waste which
should be recycled.
Precautions
The magnet (b) should be mounted on the
door or window no further than 5mm away
from the arrow on the sensor.
7. When the red LED stops ashing, the entry
sensor has successfully joined the Zigbee
network.
CAUTION: When removing cover for battery
change - Electrostatic Discharge (ESD) can
harm electronic components inside
1. Open the casing of the device by pushing
the fastening on top of the device to
remove the front panel from the back cover.
2. Replace the batteries respecting the
polarities. The entry sensor uses 2xAAA
batteries.
3. Close the casing.
4. Test the entry sensor.
INSTALLATION MANUAL
Version 1.4
The reset button is marked with the small ring
on the front of the sensor.
Placement Examples - Top View
The most benecial distance between the
sensor and the magnet is 0.2-0.5 cm.
Be aware that on magnetic surface (e.g.
metal door), the distance between the
sensor and the magnet has to be 0.1-0.3
cm.
Question and Answer IconNeed help?

Do you have a question about the Frient Entry Sensor Pro and is the answer not in the manual?

Summary

Precautions

Electrostatic Discharge Warning

Prevent ESD damage to components during battery changes.

Indoor Use Only

Mount indoors; the sensor is not waterproof.

Magnetic Field Interference

Avoid strong magnetic fields to prevent damage to electronic devices and data storage.

Getting Started

Device Setup Steps

Open casing, insert batteries respecting polarity, and close the device.

Zigbee Network Pairing

Sensor searches for Zigbee network (up to 15 min); red LED indicates search status.

Placement

Operating Environment

Place sensor indoors within 0-50°C temperature range.

Magnet and Sensor Alignment

Align magnet with sensor's triangle mark and ensure similar thickness positioning.

Signal Optimization

Relocate sensor or use smart plug to improve weak signal strength.

Mounting

Surface Preparation

Clean mounting surface thoroughly before applying the sensor.

Sensor and Magnet Attachment

Mount sensor with tape; place magnet on door/window within 5mm of sensor's arrow.

Optimal Positioning

Position magnet near sensor's grey arrow indicator; 3D plane placement is flexible.

Testing and Resetting

Functionality Test

Test by observing the green light flash when opening/closing the door/window.

Factory Reset Procedure

Press and hold reset button for 14-16 seconds; LED sequence indicates reset completion.

Modes and Fault Finding

Sensor Operational Modes

Describes LED indications for activation, gateway search, lost connection, and low battery.

Troubleshooting Common Issues

Address issues like sensor not working (battery), weak signal, or gateway search timeout.

Battery Replacement

Battery Replacement Caution

Warning: Risk of explosion with incorrect battery types; handle carefully to prevent ESD.

Battery Replacement Steps

Open casing, replace with 2xAAA batteries respecting polarity, close, and test.

Placement Examples

Top View Placement

Optimal sensor-magnet distance is 0.2-0.5 cm; 0.1-0.3 cm on magnetic surfaces.

Door Mounting Examples

Mount sensor on frame, opposite hinge; magnet on door/window within 5mm of sensor arrow.

Window Mounting Examples

Mount sensor on frame; magnet on window/sliding door, opposite hinge, within 5mm.

Regulatory Information

FCC Compliance Statement

Notes on FCC rules, limits for Class B digital devices, and managing radio frequency energy.

IC Compliance Statement

Details Canada's licence-exempt RSS standards and radiation exposure limits.

CE and Other Certifications

Confirms compliance with European Directives (RED, RoHS) and Zigbee certification.

Frient Entry Sensor Pro Specifications

General IconGeneral
BrandFrient
ModelEntry Sensor Pro
CategorySecurity Sensors
LanguageEnglish