Preliminary instructions:
READ BEFORE INSTALLING UNIT
1
1. Check window opening size: the mounting parts
furnished with this air conditioner are made to install in
a wooden sill double-hung window. The standard parts
are for window dimensions listed above. Open sash to
DPLQLPXPRIƎPP),*$
Heavy duty
NOTE: DO NOT USE ANY SCREWS OTHER THAN THOSE SPECIFIED HERE.
Do the following before starting to install unit. See illustrations below.
Check dimensions of your unit to determine model type:
Medium
Unit Height:
Unit Width:
Min. Window Opening:
Min. Window Width:
Max. Window Width:
Ǝ
Ǝ
Ǝ
Ǝ
Ǝ
Ǝ
Ǝ
Ǝ
Ǝ
Ǝ
a%78%78
sash
ƎPLQ
storm window frame or
other obstruction
FIG.1A
ƎPLQ
inner sill
outer sill
Capacity:
$
)RU0edium%78 + Heavy duty %78 $LU&RQGLWLRQHU
Pay attention to danger and safety notices.
To avoid risk of personal injurySURSHUW\GDPDJHRUSURGXFWGDPDJHGXHWRWKHZHLJKWRIWKLVdevice and sharp edges that may
be exposed:
$LUFRQGLWLRQHUVFRYHUHGLQWKLVPDQXDOSRVHDQH[FHVVLYHZHLJKt hazard. Two or more people are needed to move and install
the unit. Wear protective gloves whenever lifting or carrying the unit. $92,'WKHVKDUSPHWDOILQVRIIURQWDQGUHDUFRLOV To
SUHYHQWLQMXU\RUVWUDLQXVHSURSHUOLIWLQJDQGFDUU\LQJWHFKQiques when moving unit.
Carefully inspect location where air conditioner will be instDOOHG%HVXUHLWZLOOVXSSRUWWKHZHLJKWRIWKHXQLWRYHUDQH[tended
period of time.
Handle air conditioner with care.
Make sure air conditioner does not fall during installation.
,IDQHZHOHFWULFDORXWOHWLVUHTXLUHGKDYHWKHRXWOHWLQVWDOOed by a qualified electrician before installing unit.
Carefully read the installation manual before beginning.
)ROORZHDFKVWHSDVVKRZQ
2EVHUYHDOOORFDOVWDWHDQGQDWLRQDOHOHFWULFDOFRGHVDQGE\TXDOLILHGOLFHQVHGDXWKRUL]HGSHUVRQQHORQOy.
INSTALLATION WARNINGS AND CAUTION
window sash seal
safety lock and
Ǝlong hex
head screw
top angle
foam gasket
washer head
locking screw
frame
assembly
OHIW
side retainer
bottom rail
seal to unit
frame
assembly
ULJKW
Ǝ long
screws and
locknuts
ORFNQXWƎ
long flat
head bolt
sill angle
bracket
window
support bracket
Installation Instructions
Side louvers and the rear of the air conditioner must
have clear air space to allow enough airflow through
the condenserIRUKHDWUHPRYDO The rear of the unit
PXVWEHRXWGRRUVQRWLQVLGHDEXLOGLQJRUJDUDJH
7KHUHVKRXOGEHDWOHDVW
LQFKHVPP
FOHDUDQFHDURXQGWKHXQLW6HH),*%),*&
,QGRRUVLGH
Outdoor side
PLQ
PP
PLQ
PP
PLQ
PP
PLQ
PP
PLQ
PP
PLQ
PP
PLQPP PLQPP
PLQPP
),*&
),*%
PLQPP
Outdoor side
Indoor side
Question and Answer IconNeed help?

Do you have a question about the Frigidaire FHWW184WE2 and is the answer not in the manual?

Frigidaire FHWW184WE2 Specifications

General IconGeneral
TypeWindow Air Conditioner
Cooling Capacity (BTU)18000
Energy Efficiency Ratio (EER)12.0
Refrigerant TypeR-410A
DehumidificationYes
Power Supply (Hz)60

Summary

Installation Warnings and Safety

General Safety Precautions

Essential safety guidelines including reading manual, using assistance, proper handling, and electrical safety.

Model Dimension Check

Compare unit dimensions to determine if it's Medium or Heavy Duty model for correct installation.

Window Opening Size Verification

Ensure window opening meets minimum size requirements (min. 19" sash opening) for wooden double-hung windows.

Airflow Clearance Requirements

Maintain 11.8 inches (300mm) clearance around the unit, especially the rear, for proper heat removal.

Pre-Installation Checks

Window Condition and Storm Windows

Ensure wooden window parts are good for screws. Correct storm window fit by adding wood or removing it.

Clear Airflow Obstructions

Ensure no shrubs, trees, furniture, drapes, or blinds block airflow outside or inside the window.

Electrical Service Verification

Match power supply to unit nameplate. Use 3-prong plug; do not use extension cords or adapters.

Air Conditioner Unpacking

Remove all packing material carefully. Protect surfaces. Use assistance to move unit. Save packing for storage.

Window Mounting Preparation

Remove Unit from Cabinet

Remove packaging, front grille, filter, and front panel to access and remove the air conditioner unit from its cabinet.

Window Mounting Assembly

Install Top Angle Rail and Side Retainers

Attach foam gasket to top angle rail using screws. Secure side retainers to cabinet using screws.

Assemble and Attach Window Filler Panels

Slide filler panels into side retainers and attach frame to angle rails using screws. Do not fully tighten yet.

Window Mounting Installation

Position Cabinet in Window

Mark window center, place cabinet on sill, align center, and fasten with screws for wooden or vinyl-clad windows.

Apply Bottom Rail Foam Seal

Remove protective strip from bottom rail foam seal and apply it over screws fastening the bottom rail to the window sill.

Install Support Brackets and Sill Angle

Attach support brackets to sill angle brackets using bolts and nuts. Adjust height for proper downward tilt.

Window Mounting Final Steps

Extend and Secure Filler Panels

Raise window, loosen screws, extend filler panels, tighten screws, and attach top angle rail to window frame.

Secure Filler Panels to Window Sash

Drill starter holes, then use 1/2" hex head screws to attach filler panel top legs to the window sash.

Install Sash Seal and Safety Lock

Trim and insert window sash seal between sashes. Attach right angle safety lock to top window sash.

Install Unit and Front Panel

Slide unit into cabinet, reconnect plug, position vent lever, attach front panel with screws, and install filter and front grille.

Thru-The-Wall Installation Guide

Select Wall Location for Installation

Choose a wall location considering max thickness, side louvers, structural loads, plumbing, wiring, electrical outlets, and airflow.

Prepare Wall Opening

Prepare frame construction wall, locate stud, cut hole, and measure for opening dimensions (X and Y) based on model.

Thru-The-Wall Cabinet Installation

Build and Install Wooden Frame

Build wooden frame with interior dimensions matching model, fill space with spacers, and nail frame flush with drywall.

Position and Secure Cabinet in Wall

Slide cabinet into opening, ensure proper downward tilt (7/8"-1 1/4") for drainage, and secure bottom rail with screws.

Thru-The-Wall Masonry Installation

Prepare Masonry Wall Opening

Cut masonry wall opening similar to frame construction, use masonry nails or anchor screws to secure cabinet.

Install Lintel and Exterior Brackets

Install lintel to support wall above cabinet. Attach exterior cabinet support brackets for a weather-tight seal.