4.3 Connection to the mains supply
Connect the ICM to a 220-240 Volts power supply on a min 10A fused & grounded
socket. Do not use extension cables.
Do not connect the merchandiser to:
• a non grounded wall socket or power line
• improper supply voltage and frequency
• power supply that does not comply with the safety regulations of
the appliance or with current legislation on electrical installations
• Do not plug the cooler into a multiple outlet strip or use
extension cables.
• If the supply cord is damaged, it must be replaced by the
manufacturer or authorized service provider.
• Route the power cables in such a way that they are protected
from damage and they do not pose a risk of tripping.
4.4 Operation instructions
The thermostat is located inside the ICM. The thermostat is factory set to approx. +4.1 °C. If you
require a higher temperature (warmer), turn the thermostat knob anticlockwise. If you require a lower
temperature (colder), turn the thermostat knob clockwise.
Do not use electrical appliances inside the storage compartments of the
appliance, unless recommended by the manufacturer.