Technical data
General The cooling capacity of a cooling unit depends on
- Ambient temperature
- Delivery head
- Flow rate Q (l/min) - The flow rate Q depends on the length of the interconnecting
hosepack and the diameter of the hose.
FK 2200
Supply voltage 230 V AC
Supply voltage tolerance -30% / +15%
Frequency 50 / 60 Hz
Current draw 1,35 A
Cooling capacity
Q = 1 l/min + 20 °C (68 °F)
Q = 1 l/ min + 40 °C (104 °F)
Q = max. + 20 °C (68 °F)
Q = max. + 40 °C (104 °F)
850 W
500 W
950 W
570 W
Max. rise 25 m
82 ft.
Max. flowrate 3 l/min
0.79 gal./min
Max. pump pressure 4,3 bar
62 psi
Pump centrifugal pump 24 V
Coolant contents 1,5 l
0.4 gal.
Enclosure protection IP 23
Measurements l/w/h 540/180/180 mm
21.3/7.1/7.1 in.
Weight (without coolant) 6,6 kg
14.5 Ib.
Weight (with minimum coolant) 7 kg
15.4 Ib.
Signs S, CE

Table of Contents