St2 | E 14
At maximum wire feed speed, the motor current of the wire-feed unit motor
is outside the permitted range. Possible reasons are disengaged wire-feed
unit motors or wire feed problems.
Engage the drive units of both wire-feed unit motors, arrange the hosepack
in as straight a line as possible; check the inner liner for kinks or soiling;
check the contact pressure on the 2-roller or 4-roller drive of the push-pull
unit. Repeat the push-pull calibration. If the error message re-appears: Con-
tact After-Sales Service
Cause:
Remedy:
St2 | E 15
At maximum wire feed speed, the motor current of the push-pull unit is out-
side the permitted range. Possible reasons are disengaged wire-feed unit
motors or wire feed problems.
Engage the drive units of both wire-feed unit motors, arrange the hosepack
in as straight a line as possible; check the inner liner for kinks or soiling;
check the contact pressure on the 2-roller or 4-roller drive of the push-pull
unit. Repeat the push-pull calibration. If the error message re-appears: Con-
tact After-Sales Service.
Cause:
Remedy:
St2 | E 16
Push-pull calibration was interrupted: Quick-stop was activated by pressing
the torch trigger.
Repeat push-pull calibration
Cause:
Remedy: