4
115G
Revised: September 1, 2006
INSTALLATION, CLEANING & MAINTENANCE INSTRUCTIONS.
INSTALLATION INSTRUCTIONS:
To obtain the maximum performance, install the refrigerator on a firm, level floor. The freezer must be level to operate. It is
very important to check the level with a bubble level. Then, remove the transparent protective plastic, which covers the
freezer.
Avoid installation in a high temperature area, such as close to heat source or direct sun. To protect the continuous propane
burning, avoid installing in drafty areas. For efficient air circulation the rear of the chest freezer must remain 7 inches (18cm)
away from the wall. This appliance consumes air when operating.
ATTENTION: It is most important that a qualified technician install this freezer. Installation must conform to the
current CAN/CGA B149 Gas Installation Codes if installed in Canada. If installed in USA, the installation must conform to
the National Fuel Gas Code ANSI Z223.1.
PROPANE GAS CONNECTION:
This freezer is built to be connected to a propane tank having a pressure of 11” on the WC (30mbar). The connection should
be made with a CGA or AGA approved tubing. The following list of approved regulators can be used: REGO - 302,
MARSHAL BRASS - 210, PRECIMEX - 3001. IMPORTANT: Operating the FROSTEK with the wrong gas pressure can
destroy the cooling unit and void the guarantee.
Check that nothing is obstructing the top end of the flue tube. After the connection is completed, open the gas valve
on the propane tank and apply some soapy water on the connections. Any gas leak will result in bubbles. Should this happen,
tighten the connection, or change the connectors, as required to completely eliminate any gas leak.
This appliance is equipped with a manual shut off valve, at the entrance of the appliance. When installing, or
working on the appliance, make sure that the manual valve is closed.
The appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve
during any pressure testing of the gas supply. The test pressure should be equal to or less than 1/2 psig (3.5kPa).
ATLANTIC MINI-FRIDGE CO LTD. WILL NOT ACCEPT THE RESPONSIBILITY FOR ANY DAMAGE OR PROBLEM
RESULTING FROM IMPROPER CONNECTIONS, OR THE USE OF MATERIAL NOT MEETING THE STANDARDS OF
THE AREA IN WHICH THE INSTALLATION IS MADE.
* WARNING * : improper installation, adjustment,
alteration, service or maintenance can cause
injury or property damage. Refer to this manual.
For assistance or additional information,
consult a qualified installer, service agency or
the gas supplier.