CAP881
OCTOBER, 2012
REV.A
SEG Series
OIL-INJECTED ROTARY SCREW COMPRESSORS
OPERATOR
MANUAL
SEG-5 SEG-10
SEG-7.5 SEG-15

Questions and Answers

  • I
    ilucasAug 8, 2025
    Why FScurtis Air Compressor will not start?
    • A
      alancarlsonAug 8, 2025
      If your FScurtis Air Compressor won't start, several factors could be the cause. First, check the power supply to ensure it's properly connected. Blown fuses in the control circuit can also prevent starting, so replace any blown fuses. Inspect all connections for loose or missing wires or components within the control circuit and secure them. Ensure that the voltage settings are correct for your system (e.g., not using 230 volts in a 460-volt system). A faulty temperature sensor may also be the culprit, so consider replacing it. Finally, check and adjust the oil separator pressure.
  • N
    Nancy JohnsonAug 12, 2025
    What to do if my FScurtis SEG-5 has a high temperature shutdown?
    • A
      Audrey GallowayAug 12, 2025
      A high-temperature shutdown in your FScurtis Air Compressor can stem from several issues. Check for these potential causes: * Elevated ambient temperature: Reduce the ambient temperature around the compressor. * Low sump oil level: Refill the sump oil to the correct level. * Plugged oil filter: Replace the oil filter. * Restricted cooling airflow: Improve the cooling airflow around the unit. * Clogged heat exchanger: Clean the heat exchanger. * Thermal bypass leaking: Replace the thermal bypass. * Faulty high air temperature sensor: Replace the sensor. * Delivery pressure set too high: Adjust the delivery pressure settings. * Open panels: Ensure all panels are closed. * Restricted exhaust air: Clear any obstructions to the exhaust air.
  • C
    Carly BarnesAug 16, 2025
    Why FScurtis SEG-5 Air Compressor does not build up to the desired pressure?
    • A
      Andrew MacdonaldAug 16, 2025
      If your FScurtis Air Compressor isn't reaching the desired pressure, several factors could be responsible. Ensure the inlet valve is fully open. Check for belt slippage and tighten or replace the belt if necessary. Clean or replace a restricted inlet air cleaner. Reduce excessive air demand. Replace a defective pressure gauge. Adjust pressure limit settings if they are too low. Inspect and clean the separator if there's excessive pressure drop. Inspect and repair a solenoid valve that is stuck open. Inspect and service the air end for any malfunction. If the compressor is too small, consider upgrading to a larger one. Finally, inspect and adjust the safety valve if it keeps discharging.
  • D
    Daniel BowersAug 21, 2025
    How to reduce high power consumption of FScurtis SEG-5 Air Compressor?
    • T
      trevor09Aug 21, 2025
      High power consumption in your FScurtis Air Compressor may be due to several reasons. A plugged separator or aftercooler can cause this, so clean them. Ensure the air pressure switch setting is correct by adjusting it. Verify and correct the line voltage if it's too low. Balance electrical phases if there's an imbalance. Inspect and repair the motor if imminent failure is suspected. Similarly, inspect and service the air end if imminent failure is suspected. Address belt slippage by tightening or replacing the belt. Finally, inspect and secure any loose electrical connections.
  • M
    Michael BakerAug 26, 2025
    Why FScurtis SEG-5 Air Compressor starts but shuts down immediately?
    • V
      velasquezcourtneyAug 26, 2025
      If your FScurtis Air Compressor starts but shuts down immediately, consider these potential causes. Replace the pressure transducer or timer if there's a failure. Reduce air temperature if it's too high. Inspect and secure any loose or missing electrical components. Adjust the pressure limit settings if they're set too low. Inspect the motor and load conditions if motor overloads trip. Verify and correct the voltage supply if it's too low.
  • J
    jeremiah89Aug 30, 2025
    What causes the safety valve to discharge on my FScurtis SEG-5?
    • K
      Krista DavisAug 30, 2025
      If the safety valve on your FScurtis Air Compressor is discharging, it could be due to several reasons. The over pressure may not be set correctly, so adjust the pressure settings. Inspect and repair the inlet valve if it's not closing properly in relation to air demand. Clean the separator if it's plugged. Replace the minimum pressure check valve if it's faulty. Finally, replace the safety valve if it's faulty.
  • L
    Lisa MeadowsSep 2, 2025
    What to do if FScurtis SEG-5 Air Compressor will not load?
    • C
      Catherine CortezSep 2, 2025
      If your FScurtis Air Compressor won't load, it could be due to a few reasons. The pressure might be set too low; increase the pressure setting. The inlet valve may not be opening, so repair or replace it. A faulty solenoid valve could also be the cause; repair or replace it as needed.