14
PARADOX CONTACT ID
EVENT GROUP NO SUB-GROUP NO CONTACT
ID CODE
EVENT/
RESTORE
ZONE/
USER
44 = New Trouble
01 = AC Failure 301 1 0
02 = Batt Fail 302 1 0
04 = Bell Current Overload 320 1 0
05 = Bell disconnected 320 1 0
08 = Fail To Communicate Tel 1 350 1 1
09 = Fail to Communicate Tel 2 350 1 2
10 = fail to Communicate Pager 350 1 3
11 = fail to communicate voice 350 1 4
45= Trouble Restore 01 = AC Failure Restore 301 3 0
02 = Batt Fail restore 302 3 0
04 = Bell Current Overload Rest 320 3 0
46 = Bus/wireless module new trouble 01 = tamper Trouble 137 1 0
48 = Special (Partition 1 only)
01 = Reporting Test 602 1 0
04 = Installer Entered Prog Mode 627 3 0
05 = Installer Exited Prog Mode 628 1 0
07 = Maintenance Exited Prog Mode
49 = Low Battery on Zone 01-32 = Zone Number 302 1 ZONE
50 = Low Battery on Zone Restore 01-32 = Zone Number 302 3 ZONE
51 = Zone supervision trouble 01-32 = Zone Number 147 1 ZONE
52 = Zone Supervision restore 01-32 = Zone Number 147 3 ZONE
53 = Wireless Module Sup Trbl 147 1 ZONE
54 = Wireless Module Sup Rest 147 3 ZONE
55 = Wireless Module Tamper Trbl 144 1 ZONE
56 = Wireless Module Tamper Rest 144 3 ZONE