Problem Solving
556
Problem Solving
15
027-522
[Cause] During forwarding using SMB of the Scan to PC service, the
scanned image file could not be created on the SMB server
because of one of the following reasons:
z
The specified file name already exists.
z
The specified file name has already been used.
z
The specified file name exists as a directory.
z
Invalid characters are used in the file name.
[Remedy] Take one of the following measures:
z
Check whether the specified file name can be used in the
save location.
z
Check whether the specified file name has been used by
another user.
z
Check whether the specified file name has been used for
another file or folder.
027-523
[Cause] The machine failed to transfer data using SMB of the Scan to PC
service because a folder could not be created on the SMB server.
The specified folder already exists.
[Remedy] Check whether the specified name is being used for another file
or folder on the SMB server.
027-524
[Cause] The machine failed to transfer data using SMB of the Scan to PC
service because a folder could not be created on the SMB server.
The specified folder already exists.
[Remedy] Check whether the specified name is being used for another file
or folder on the SMB server.
027-525
[Cause] During forwarding using SMB of the Scan to PC service, a file
could not be deleted from the SMB server because of one of the
following reasons:
z
The file does not exist.
z
The file is opened.
z
The specified file name is being used as a directory.
[Remedy] Check whether the file is not being used by another user at the
specified save location.
027-526
[Cause] The machine failed to delete the lock directory on the SMB
server while transferring data using SMB of the Scan to PC
service.
[Remedy] If the lock directory (*.LCK) exists in the destination, delete it
manually, and then execute the operation again.
027-527
[Cause] During forwarding using SMB of the Scan to PC service, a folder
could not be deleted from the SMB server because of one of the
following reasons:
z
The file does not exist.
z
The directory is not empty.
z
The specified directory name does not exist.
[Remedy] Check whether the file is not being used by another user at the
specified save location.
027-528
[Cause] The machine failed to transfer data using SMB of the Scan to PC
service because no space is available at the save location on the
SMB server.
[Remedy] Check whether the save location has free space.