Do you have a question about the FujiFilm RYB201S3-VBC and is the answer not in the manual?
Rated Output Power | 200 W |
---|---|
Communication Interface | RS-485 |
Control Method | PWM |
Protection Features | Overcurrent, Overvoltage, Undervoltage |
Operating Temperature | 0°C to 55°C |
Humidity | 90% (non-condensing) |
Vibration | 5.9 m/s² max |
Series | RYB |
Details critical DANGER and CAUTION indications for safe operation.
Outlines the two stages: wiring checks and parameter setup with host controller.
Details checks and operational steps for the initial system test phase.
Describes checks and operational steps for the final test in the operational state.
Explains parameter categories and methods for editing via keypad or PC loader.
Lists all basic, system, and control setting parameters with ranges and initial values.
Details parameters for pulse correction, input forms, rotation, and tuning modes.
Covers signal allocation for I/O terminals and specific functions like alarms and brakes.
Details parameters for tuning, filters, anti-resonance, and command follow-up control.
Guides through auto, semi-auto, and manual tuning for optimal servo performance.
Provides methods for tuning when basic adjustment is insufficient or vibration occurs.
Explains dumping control and anti-resonance frequency settings for vibration suppression.
Guides on entering and editing parameter values, including decimal points and range limits.
Covers manual operation, alarm reset, initialization, phase-Z, and auto-tuning gain settings.
Lists inspection items for servomotor and servo amplifier, emphasizing safety precautions.
Explains memory back-up, initialization, copying, and fault display troubleshooting.
Details troubleshooting steps for servomotor rotation, hunting, positioning accuracy, and alarms.