EasyManua.ls Logo

FujiFilm RYB401S3-VBC User Manual

FujiFilm RYB401S3-VBC
252 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
FUJI AC SERVO SYSTEM
USER’S MANUAL
MEH395

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the FujiFilm RYB401S3-VBC and is the answer not in the manual?

FujiFilm RYB401S3-VBC Specifications

General IconGeneral
Communication InterfaceRS-485
Rated Output Power400W
Control MethodPWM Control
Protection FeaturesOvercurrent, Overvoltage, Overtemperature, Short Circuit
Operating Temperature0 to +55 °C
Storage Temperature-20°C to 65°C
Humidity20% to 90% (Non-condensing)
Vibration Resistance5.9 m/s²

Summary

SAFETY INSTRUCTIONS

DANGER and CAUTION Indications

Defines DANGER and CAUTION warnings, highlighting specific hazards.

Feature 1: Vibration Suppression

INSTALLATION

2-1) Servomotor

Covers servomotor storage, operating environment, and mounting.

2-2) Servo amplifier

Covers servo amplifier storage, operating environment, and mounting.

Servomotor Handling Precautions

Servo Amplifier Mounting and Spacing

WIRING

3-2) Servo amplifier

Details commercial power supply and main circuit terminal wiring.

3-3) Servomotor

Explains servomotor power wiring and connector details.

3-5) Standard connection diagrams

Provides standard wiring diagrams for various configurations.

Wiring Diagram: 3-Phase 200V (Without Brake)

TEST OPERATION

4-2) First stage

Details checks and procedures for the initial test operation stage.

4-3) Second stage

Lists items to check and procedures for the final test operation stage.

PARAMETERS

5-1) Parameter configuration

Introduces parameter groups, their functions, and locations.

Parameter Editing Methods

Basic Settings: Tuning Mode Selection

System Setting: Operation Command [RUN]

System Setting: Forced Stop and Detection

ADJUSTMENT OF SERVO

6-1) Basic adjustment

Covers basic servo tuning procedures including auto tuning.

SPECIAL ADJUSTMENT

Command Follow-up Control: Parameter Setting

KEYPAD PANEL

INSPECTION AND MAINTENANCE

9-1) Inspection

Covers inspection procedures and safety precautions.

Fault Diagnosis: Servomotor Does Not Rotate

Faults with Alarm Indication and Remedy

SPECIFICATIONS

Related product manuals