Fusion Splicer 36S/37S/38S/41S Quick Reference Guide
Visible Splice Defects and Error Message
Contact Address
Q-41S-E01
Error Message Reason Solution
Too Long Fiber
The Cleave length (bare fiber
part) is too long.
Dust or dirt is on the objective
lens cover.
Cleave by forcing a holder tip of fiber cutting, and
pressing to a position.
Execute the [Dust Check]. Clean the lens cover
when dust or dirt exists.
Too Dusty Fiber
Dust or dirt is on the fiber
surface.
Dust or dirt is on the objective
lens cover.
[Cleaning Arc] time is too short
or “OFF”.
Prepare the fiber again.
Execute the [Dust Check]. Clean the lens cover
when dust or dirt exists.
Set the [Cleaning Arc] time. When splicing carbon
coated fibers, set to more time.
ZL/ZR Motor
Overrun
The fiber is correctly at the
bottom of the V-groove.
The Cleave length (bare fiber
part) is too short.
Press RESET, and set the fiber again to seat it
correctly at the bottom of the V-groove.
Cleave by forcing a holder tip of fiber cutting, and
pressing to a position. Check the fiber length.
Large Cleave Angle
Bad fiber end-face.
[Cleave Limit] is set too low.
Check the condition of the fiber cleaver. If the blade
is worn, rotate the blade to a new position.
Increase the [Cleave Limit] to an adequate Limit.
Cleave Shape NG Bad fiber end-face.
Check the condition of the fiber cleaver. If the blade
is worn, rotate the blade to a new position.
Fujikura Ltd.
1-5-1 Kiba, Koto-ku, Tokyo 135-8512 Japan
Phone : +81-3-5606-1164 Fax : +81-3-5606-1534
https://www.fusionsplicer.fujikura.com
Fujikura (CHINA) Co., Ltd.
7
th
Floor, Hang Seng Bank Tower 1000Lujiazui Ring Road, Pudong New Area ShanghaiZIP200120, China
Phone : +86-21-6841-3636 Fax : +86-21-6841-2070 http://www.fujikura.com.cn
Fujikura Asia Ltd.
438A Alexandra Road,Block A Alexandra Technopark #08-03, Singapore 119967
Phone : +65-6278-8955 Fax : +65-6273-7705 http://www.fujikura.com.sg
Fujikura Europe Ltd.
C51 Barwell Business Park, Leatherhead Road, Chessington, Surrey KT9 2NY. UK.
Phone : +44-20-8240-2000 Fax : +44-20-8240-2010 https://www.fujikura.co.uk
AFL
260 Parkway East, Duncan, SC 29334 USA
Phone : +1-800-235-3423 Fax : +1-800 -926-0007 https://www.AFLglobal.com
Authorized Splicer Distributor
Bubble
Separation
Fat
Too Thin
Fusion Splicer 36S/37S/38S/41S Quick Reference Guide
**Pull*Hold
Splicing Operation
250μm
Cleave Length
900μm
5~16mm
1/5”~2/3”
5~16mm
1/5”~2/3”
When splicing only standard
SM fibers, “SM AUTO” mode is
recommended.
Heating Mode has been the
optimal conditions for the
sleeve made from FUJIKURA.
Turning splicer ON
Confirming splice and heater modes
Cleaning coating or sheath of fiber
Placing protection sleeve over fiber
Cleaning fiber
Cleaving fiber
Loading fiber onto splicer
Removing spliced fiber
Centering protection sleeve in tube heater
Completed
Stripping fiber
Centering spliced point in tube heater
Visual inspection on LCD during splice
*Hold the fiber at edge of splicer body
**Gentry pull the fiber.
When splicer indicates following message, splice loss may be high
“Arc discharge is not stable. Electrodes should be stabilized to reform the arc discharge.”
Load prepared SM fibers onto splicer in order to stabilize electrodes. After completeing it, re-splice fibers.
When an altitude changes drastically, stabilizing elctrodes must be excecuted before splicing.
Make sure the stripped fiber is
free of coating debris or
contamination.
Use only 99% or better purity
alcohol.
Do not allow the cleaved fiber
ends to touch anything or
become contaminated.
Place the fiber end between
V-groove edge and Electrode
center.
Note
Closing wind protector and Press
SET
Closing tube heater lidand Press HEAT
1/2”
3/64”~1/8”
1~3mm
13mm

Other manuals for Fujikura 41S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujikura 41S and is the answer not in the manual?

Fujikura 41S Specifications

General IconGeneral
Model41S
Alignment MethodCore Alignment
Return Loss≥60 dB
Automatic Heating StartYes
Operating Temperature Range-10 °C to +50 °C
Applicable FibersSM, MM, DS, NZDS
Cladding Diameter80 μm - 150 μm
Fiber Cleave Length8-16 mm
Splice Loss0.02 dB (SMF), 0.01 dB (MMF)
Applicable Protection Sleeve Length40 mm, 60 mm
Data OutputUSB
Screen4.7 inch color LCD monitor
Power SupplyAC 100-240V, 50/60Hz, DC 12V
Fiber TypesSM (ITU-T G.652&G.657), MM (ITU-T G.651), DS (ITU-T G.653), NZDS (ITU-T G.655)