EasyManua.ls Logo

Fujitsu AJHA54LALH - User Manual

Fujitsu AJHA54LALH
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EnglishDeutschFrançaisEspañolItalianoEλληvIkάPortuguêsРусскийTürkçe
INSTALLATION MANUAL
INSTALLATIONSANLEITUNG
MANUEL D’INSTALLATION
MANUAL DE INSTALACIÓN
MANUALE D’INSTALLAZIONE
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ
MANUAL DE INSTALAÇÃO
РУКОВОДСТВО ПО УСТАНОВКЕ
KURULUM KILAVUZU
OUTDOOR UNIT
AUSSENGERÄT
UNITÉ EXTÉRIEURE
UNIDAD EXTERIOR
UNITÀ ESTERNA
ΕΞΩΤΕΡΙΚΉ ΜΟΝΆΔΑ
UNIDADE EXTERIOR
ВНЕШНИЙ МОДУЛЬ
DIŞ ÜNİTE
For authorized service personnel only.
Nur für autorisiertes Fachpersonal.
Uniquement réservé aux techniciens agréés.
Sólo para personal de servicio autorizado.
A uso esclusivo del personale tecnico autorizzato.
Μόνο για εξουσιοδοτημένο τεχνικό προσωπικό.
Apenas para técnicos de assistência autorizados.
Только для авторизованного обслуживающего персонала.
Yalnızca yetkili servis personeli için.
PART NO. 9380545026-02
TM
AJYA36LALH
AJYA40LALH
AJYA45LALH
AJYA54LALH
AJHA36LALH
AJHA40LALH
AJHA45LALH
AJHA54LALH
9380545026-02_IM.indb cover19380545026-02_IM.indb cover1 19/08/2013 17:19:1419/08/2013 17:19:14
Question and Answer IconNeed help?

Do you have a question about the Fujitsu AJHA54LALH and is the answer not in the manual?

Fujitsu AJHA54LALH Specifications

General IconGeneral
BrandFujitsu
ModelAJHA54LALH
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions

About the Unit

Precautions for using R410 A refrigerant

Guidelines and precautions for handling R410A refrigerant safely.

Special tools for R410 A

List of specialized tools required for R410A refrigerant systems.

Accessories

Details on included accessories for the unit installation.

Installation Work

Selecting an installation location

Guidelines for choosing an appropriate and safe installation site for the outdoor unit.

Drain processing

Instructions for proper drainage system setup to prevent water damage.

Installation dimensions

Specifications for required space and clearances around the outdoor unit.

Transporting the unit

Safe methods and precautions for moving the outdoor unit.

Installation the unit

Steps and considerations for physically mounting the outdoor unit.

System Configuration

System configuration

Overview of the system's components and their interconnections.

Pipe selection

Guidelines for selecting appropriate piping sizes based on unit capacity and length.

Protection of pipes

Methods for protecting refrigerant pipes from damage and environmental factors.

Pipe Installation

Brazing

Procedure and precautions for brazing refrigerant pipes.

Indoor unit pipe connections

How to connect refrigerant pipes to the indoor units.

Opening the knockout hole

Steps for creating openings in the unit casing for pipe routing.

Pipe connection

Detailed instructions for connecting refrigerant pipes.

Handling precautions for the valves

Safe operation procedures for unit valves.

Electrical Wiring

The precautions of electrical wiring

Essential safety guidelines for electrical wiring.

Knockout hole

Creating openings for wiring passage and protecting cable edges.

Selecting power supply cable and breaker

Guidance on choosing appropriate power cables and circuit breakers.

Transmission line

Instructions for wiring the communication and control lines.

Wiring method

Detailed instructions and diagrams for connecting wires.

External input and external output

Terminal position

Location of external input/output terminal blocks on the PC board.

External input terminal

Description of external input terminals and their functions.

External output terminal

Description of external output terminals and their functions.

Field Setting

Field setting switches

Overview of the PC board switches for various settings.

DIP switch setting

Configuration settings using DIP switches.

Rotary switch setting

Setting refrigerant circuit addresses using rotary switches.

Push button setting

Using push buttons on the PC board to configure unit functions.

Address setting for signal amplifiers

Address setting for signal amplifiers

Procedure for setting addresses for signal amplifiers.

Automatic address setting for signal amplifiers

How to automatically set addresses for signal amplifiers.

Indoor unit address setting

Indoor unit address setting

Methods for manually and automatically setting indoor unit addresses.

Procedures to enable automatic address setting on indoor units

Steps to enable the automatic address setting function for indoor units.

Resistance measurement of transmission cable

Pipe Installation II

Sealing test

Procedure for testing refrigerant lines for leaks.

Vacuum process

Steps for evacuating the refrigerant system using a vacuum pump.

Additional charging

Procedure for adding refrigerant to the system.

Installing insulation

Installing insulation material on refrigerant pipes to prevent condensation.

Filling with putty

Using putty to seal gaps and prevent water entry.

Test Operation

Indoor unit connection check

Verifying the connection status between indoor and outdoor units.

Things to confirm before starting the Indoor unit connection check

Pre-checks required before performing the indoor unit connection check.

Restrictions applicable when performing the Indoor unit connection check

Limitations and duration for the indoor unit connection check.

Operating procedure for Indoor unit connection check

Step-by-step guide for the indoor unit connection check process.

Error displays

Interpreting error codes displayed during the connection check.

Test run

Test run method

Checklist

LED Display

Normal operation mode

Interpreting LED indicators during normal unit operation.

Error display mode

Understanding LED indicators for error conditions.

Information

Main contents of label

Details about the information found on the unit's label.

Related product manuals