Details of control output function

Operation status
Function
setting
External Input and
Output PCB
External output Output signal Status
Rotary switch
60-00 — Output of indoor unit CN47
Off → On Operation
On → Off Stop
— 1, B, C, D
External Input and
Output PCB
Ex OUT 1
Off → On Operation
On → Off Stop
The output is low when the unit is stopped.
CN47
On
Off
Ex OUT 1
Indoor unit operation
On
Off
On
Off

Error status
Function
setting
External Input and
Output PCB
External output Output signal Status
Rotary switch
60-09 — Output of indoor unit CN47
Off → On Error
On → Off Normal
— 2
External Input and
Output PCB
Ex OUT 1
Off → On Error
On → Off Normal
— 1, C
External Input and
Output PCB
Ex OUT 2
Off → On Error
On → Off Normal
— D
External Input and
Output PCB
Ex OUT 3
Off → On Error
On → Off Normal
The output is on when an error is generated for the indoor unit.
Error
Normal
On
Off
CN47
On
Off
Ex OUT 1, 2, 3
Indoor unit
- 195 -
12-1. Compact cassette type, Medium static pressure duct type (ARXH22KMTAP), and
Ceiling type
12. External input and output
4-5 UNIT
MULTI-SPLIT TYPE
4-5 UNIT
MULTI-SPLIT TYPE

Table of Contents

Other manuals for Fujitsu AO G12KATA Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AO G12KATA Series and is the answer not in the manual?

Fujitsu AO G12KATA Series Specifications

General IconGeneral
BrandFujitsu
ModelAO G12KATA Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals