EasyManua.ls Logo

Fujitsu AOTS18LDL - User Manual

Fujitsu AOTS18LDL
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
KEEP THIS OPERATION MANUAL
FOR FUTURE REFERENCE
FUJITSU GENERAL LIMITED
OPERATING MANUAL
P/N9315231031-01
Indoor Unit
ASTB18LDC
Outdoor Unit
AOTS18LDC
HEAT & COOL MODEL
(REVERSE CYCLE)
ROOM AIR CONDITIONER
WALL MOUNTED TYPE
R410A
REFRIGERANT
This Air Conditioner contains and operates
with refrigerant R410A and Polyol Ester oil.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance and/or service of this product.

Questions and Answers

Summary

SAFETY PRECAUTIONS

FEATURES AND FUNCTIONS

Inverter Technology

Explains the use of large power initially for quick temperature setting, then low power for economy.

Coil Dry Operation Function

Dries the indoor unit to prevent mold and restrain bacteria growth.

Swing Operation Function

Automatically swings louvers for wide air distribution to every room corner.

Air Cleaning Mode Function

Utilizes air conditioner power to quickly purify the air in the room.

Sleep Timer Function

Gradually adjusts thermostat during operation for sleep comfort and automatic shutdown.

NAME OF PARTS

Indoor Unit Components

Identifies and illustrates the various parts of the indoor air conditioner unit.

Remote Control Unit Components

Identifies and illustrates the parts of the wireless remote control.

PREPARATION

Power Connection and Battery Loading

Steps for connecting the power supply and loading batteries into the remote control.

Setting the Current Time

Procedure to set the current time on the remote control unit's clock.

Remote Control Unit Usage

Guidelines for operating the remote control unit, including range and signal reception.

OPERATION

Selecting Operation Mode

How to choose between COOL, DRY, HEAT, and FAN operating modes.

Setting Thermostat and Fan Speed

Adjusting the desired room temperature and fan speed settings.

Super Quiet Operation

Activates reduced airflow for quieter operation, suitable for quiet environments.

Auto Changeover Operation

Unit automatically selects mode based on detected room temperature conditions.

Detailed Mode Operations

Explains specific operational details for Heating, Cooling, Dry, and Fan modes.

AIR CLEANING OPERATION

Activating Air Cleaning

Steps to initiate the air cleaning mode alongside air conditioning.

Stopping Air Cleaning

How to stop the air cleaning function or the entire unit operation.

Air Cleaning Precautions

Important safety notes and usage considerations for the air cleaning function.

TIMER OPERATION

Setting ON;OFF Timers

How to set a single ON or OFF timer for automatic operation.

Using the Program Timer

Setting sequential ON and OFF timers within a 24-hour period.

Managing Timer Functions

Covers canceling, changing, and stopping timer operations.

SLEEP TIMER OPERATION

Activating the Sleep Timer

How to set the sleep timer for automatic temperature adjustment and shutdown.

Sleep Timer Functionality

Explains temperature adjustments during sleep timer operation for comfort.

Managing Sleep Timer

Covers changing, canceling, and stopping the sleep timer.

ADJUSTING THE DIRECTION OF AIR CIRCULATION

Vertical Airflow Adjustment

How to adjust the up-down airflow direction using the remote control.

Horizontal Airflow Adjustment

Manual adjustment of the left-right louvers for desired airflow direction.

Airflow Adjustment Precautions

Safety warnings and usage notes for adjusting airflow direction.

SWING OPERATION

Activating Swing Mode

Enables automatic up/down movement of the louvres for air distribution.

Swing Mode Details

Explains swing ranges for different operating modes (Cooling, Heating, Fan).

COIL DRY OPERATION

Activating Coil Dry Mode

Starts the 30-minute coil drying process to prevent mold and bacteria.

Coil Dry Mode Details

Information on coil dry operation duration, purpose, and limitations.

MANUAL AUTO OPERATION

Using Main Unit Controls

Operating the unit directly from the main control panel when remote is unavailable.

CLEANING AND CARE

Cleaning the Intake Grille

Step-by-step guide to safely removing and cleaning the air intake grille.

Cleaning the Air Filter

Instructions for removing, cleaning, and reinstalling the air filters.

CLEANING THE PLASMA AIR CLEANING FILTER

Air Cleaning Maintenance Indicators

Explains indicator lamp signals for filter maintenance and cleaning needs.

Cleaning the Dust Collection Unit

Steps to clean the dust collection unit and its associated filter.

Air-Cleaning Filter Installation;Removal

Guide to properly install or remove the air cleaning and deodorizing filter.

Air-Cleaning Filter Care

Recommendations for filter replacement intervals and proper storage.

TROUBLESHOOTING

Basic Operation Checks

Initial checks for non-operation, noises, smells, mist, steam, and airflow issues.

Air Cleaning Lamp Status

Interpreting flashing patterns of the air clean indicator lamp for maintenance.

Advanced Troubleshooting Checks

Further checks for poor cooling performance, remote setting discrepancies, and unit operation.

Handling Persistent Issues

Steps for persistent problems, burning smells, or flashing error lamps, including consulting service.

OPERATING TIPS

Heating Performance and Defrosting

Explains heating efficiency limitations and the automatic defrosting function.

Auto Restart Functionality

Details how the unit automatically resumes operation after a power interruption.

Operating Temperature and Humidity Guidelines

Specifies suitable environmental conditions for Cooling, Dry, and Heating modes.

Energy Saving Recommendations

Tips for reducing power consumption and proper shutdown procedures.

Overview

This document serves as the Operating Manual for the FUJITSU INVERTER Heat & Cool (Reverse Cycle) Room Air Conditioner, specifically for wall-mounted types. It covers both the Indoor Unit (ASTB18LDC) and the Outdoor Unit (AOTS18LDC). The manual emphasizes safety precautions, operational procedures, and maintenance guidelines to ensure efficient and safe use of the air conditioner.

Function Description

The FUJITSU INVERTER air conditioner is designed to provide both heating and cooling for a room, utilizing a reverse cycle system. Its inverter technology allows for rapid attainment of the desired room temperature, followed by a switch to a low-power setting for economic and comfortable operation, maintaining a constant temperature.

The unit features an AUTO CHANGEOVER mode, which automatically switches between cooling, dry, and heating operations to maintain the set temperature. This ensures the room temperature remains constant without manual intervention.

For enhanced air quality, the air conditioner includes an AIR CLEANING MODE that purifies the air in the room. This mode relies on the unit's power to effectively remove dirt, dust, cigarette smoke, and pollen. An ELECTRONIC AIR CLEAN FILTER is integrated into the dust collection unit, using electrical power to charge the filter, remove contaminants, collect dust, and reduce odors and bacterial activity.

The SWING OPERATION feature automatically moves the Air Flow Direction Louvers up and down, ensuring that conditioned air reaches every part of the room. This helps in achieving uniform temperature distribution.

For quieter operation, the SUPER QUIET OPERATION mode reduces the indoor unit's airflow, making it ideal for use during sleep or in environments where low noise is preferred.

The air conditioner also incorporates a COIL DRY OPERATION function. This feature allows the indoor unit to be dried after use, preventing mold growth and inhibiting bacterial breeding, thus contributing to a cleaner and healthier indoor environment.

Usage Features

The air conditioner is controlled via a WIRELESS REMOTE CONTROL UNIT, offering convenient operation from a distance of about 7 meters. The remote control allows users to select various modes, adjust temperature, fan speed, and set timers.

Mode Selection: Users can choose between AUTO, COOL, DRY, HEAT, and FAN modes using the MASTER CONTROL button. Temperature Setting: The SET TEMP. buttons allow precise adjustment of the thermostat setting within specified ranges for each mode (e.g., 18 to 30 °C for Cooling/Dry). Fan Speed Control: The FAN CONTROL button cycles through AUTO, HIGH, MED, LOW, and QUIET fan speeds. In AUTO mode, the fan speed adjusts optimally for heating or cooling, while in FAN mode, it runs at a low speed to circulate air. Air Flow Direction: Vertical airflow can be adjusted using the SET button on the remote control, offering different ranges for cooling/dry, heating, and fan modes. Horizontal airflow is adjusted manually by moving the Right-Left louvers.

Timer Operations:

*   **ON Timer/OFF Timer:** Allows users to program the unit to start or stop at a specific time.
*   **PROGRAM TIMER:** Integrates OFF timer and ON timer operations into a single sequence, enabling the unit to turn off and then turn on (or vice versa) within a 24-hour period.
*   **SLEEP TIMER:** Automatically modifies the thermostat setting during sleep to prevent excessive warming or cooling. In heating mode, the thermostat setting is gradually lowered, and in cooling/dry mode, it is gradually raised, before the unit automatically turns off after the set time.

MANUAL AUTO OPERATION: In cases where the remote control is unavailable, the unit can be operated directly from the main unit control panel, defaulting to AUTO mode with standard fan speed and thermostat setting.

Maintenance Features

Regular maintenance is crucial for the air conditioner's performance and longevity. The manual provides detailed instructions for cleaning various components.

Removable Open Panel: The indoor unit's Open Panel can be easily removed, facilitating access for cleaning and maintenance.

Cleaning the Intake Grille:

1.  The Intake Grille can be removed by lifting it forward from its lower ends and opening it wide until it becomes horizontal.
2.  It should be cleaned with water, removing dust with a vacuum cleaner or by wiping with warm water and a soft cloth, then dried thoroughly.
3.  Reinstallation involves aligning mounting shafts and pressing the grille into place.

Cleaning the Air Filter:

1.  The air filter is accessed by opening the Intake Grille. Its handle is lifted, and two lower tabs are disconnected to pull it out.
2.  Dust can be removed with a vacuum cleaner or by washing the filter in a solution of mild detergent and warm water. It must be dried thoroughly in a shaded place before reinstallation.
3.  The filter should be cleaned every two weeks during normal use to prevent reduced airflow, operating efficiency, and increased noise.

Cleaning the Plasma Air Cleaning Filter (Dust Collection Unit):

1.  The dust collection unit is removed by securely grasping its handle and pulling it out after opening the intake grille and removing the right air filter.
2.  The air cleaning & deodorizing filter is then removed from the cleaning unit by opening the filter case.
3.  The plasma filter unit should be soaked in warm water (40-45°C) for 10-15 minutes. For very dirty filters, a diluted mild synthetic laundry detergent can be used. It should be gently moved up and down, rinsed with clean water, shaken to drain water, and dried completely in the shade.
4.  The manual warns against disassembling the unit, using hot water, abrasive items, or inserting brushes inside, as these can cause damage.
5.  The AIR CLEAN Indicator Lamp (green) flashes slowly after approximately 400 hours of use, indicating that maintenance is required. After 500 hours, it flashes quickly, and air cleaning ceases until maintenance is performed.
6.  The air cleaning & deodorizing filter should be changed approximately every 2 years to ensure good performance, provided it is cleaned every six months. Only authorized filters (UTR-FA14) should be used.

Coil Dry Operation: This function helps dry the indoor unit's coil, preventing mold and bacteria. It runs for 30 minutes and stops automatically.

Safety Precautions: The manual stresses the importance of disconnecting power before cleaning, ensuring secure installation of filters and grilles, and avoiding contact with the heat exchanger to prevent injury. It also advises against using harsh cleansers or volatile agents on the unit's body.

Fujitsu AOTS18LDL Specifications

General IconGeneral
RefrigerantR410A
TypeSplit Air Conditioner
Cooling Capacity18, 000 BTU/h
Heating Capacity18, 000 BTU/h
SEER18
HSPF9.0
Coefficient of Performance (COP)3.80
Power Supply1 Phase, 60Hz
Noise Level (Indoor)42 dB
Noise Level (Outdoor)52 dB