Trouble shooting 21
Forecast of Cause:
Check Point 2 : Check external cause at Indoor and Outdoor (Voltage drop or Noise)
Check Point 1 : Check indoor and outdoor installation condition
OK
OK
OKOK
No Operation (Power is ON)
1. Setting/ Connection failure 2. External cause
3. Electrical component defective
Are these Indoor Unit, Outdoor Unit, and Remote Control suitable model numbers to connect?
>> If there is some abnormal condition, correct it by referring to Installation manual and
Data & Technical Manual.
Turn off Power and check/ correct followings.
Is there loose or removed communication line of Indoor Unit and Outdoor Unit?
Instant drop ----- Check if there is a large load electric apparatus in the same circuit.
Momentary power failure ----- Check if there is a defective contact or leak current in the power supply circuit.
Noise ----- Check if there is any equipment causing harmonic wave near electric line.
(Neon bulb or electric equipment that may cause harmonic wave)
Check the complete insulation of grounding.
02-23
If the symptom does not change by above Check 1, 2, replace Main PCB.

Other manuals for Fujitsu AOU12RL2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOU12RL2 and is the answer not in the manual?

Fujitsu AOU12RL2 Specifications

General IconGeneral
BrandFujitsu
ModelAOU12RL2
CategoryAir Conditioner
LanguageEnglish

Related product manuals