Model: ASU24RLF
AFR CFM 659
Indoor temperature
°FDB 64 70 75 80 85 90
°FWB 54 60 63 67 71 73
Outdoor temperature
°FDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW kBtu kW
-5 19.12 11.45 0.30 21.30 11.51 0.30 23.48 12.56 0.31 24.19 13.56 0.31 25.64 13.52 0.32 27.11 14.39 0.32
5 19.10 11.47 0.37 21.28 11.54 0.38 23.46 12.58 0.38 24.17 13.59 0.39 25.62 13.54 0.39 27.09 14.42 0.39
14 19.06 11.37 0.45 21.23 11.44 0.45 23.42 12.46 0.46 24.13 13.45 0.46 25.56 13.40 0.47 27.04 14.29 0.47
23 19.06 11.60 0.52 21.20 11.67 0.52 23.39 12.72 0.53 24.13 13.73 0.54 25.56 13.66 0.54 27.02 14.57 0.54
32 19.03 11.81 0.59 21.20 11.88 0.60 23.39 12.95 0.60 24.11 13.98 0.61 25.53 13.93 0.61 26.99 14.86 0.62
41 19.03 11.35 0.65 21.18 11.44 0.66 23.37 12.44 0.67 24.11 13.43 0.68 25.53 13.38 0.68 26.99 14.27 0.69
50 18.98 11.58 0.74 21.12 11.67 0.75 23.32 12.72 0.76 24.03 13.73 0.77 25.46 13.66 0.77 26.92 14.57 0.78
59 18.63 11.33 0.82 20.74 11.40 0.83 22.86 12.42 0.84 23.58 13.41 0.85 24.98 13.34 0.85 26.41 14.23 0.86
67 17.91 11.05 0.95 19.96 11.12 0.97 21.97 12.15 0.98 22.66 13.10 0.99 24.02 13.07 1.00 25.39 13.92 1.01
77 19.31 11.57 1.37 21.50 11.63 1.39 23.71 12.69 1.41 24.43 13.72 1.42 25.90 13.65 1.43 27.36 14.54 1.44
87 18.36 11.23 1.53 20.47 11.29 1.55 22.55 12.32 1.58 23.27 13.31 1.58 24.63 13.24 1.60 26.03 14.13 1.61
95 17.37 10.88 1.70 19.35 10.92 1.72 21.33 11.94 1.75 21.97 12.86 1.76 23.30 12.83 1.78 24.60 13.65 1.80
104 16.24 10.47 1.86 18.08 10.54 1.89 19.93 11.50 1.92 20.54 12.42 1.93 21.77 12.35 1.95 23.00 13.17 1.97
115 12.35 9.21 1.56 13.75 9.28 1.58 15.18 10.13 1.61 15.63 10.92 1.61 16.58 10.88 1.63 17.50 11.60 1.65
AFR
m
3
/h
1,120
Indoor temperature
°CDB 17.8 21.1 23.9 26.7 29.4 32.2
°CWB 12.2 15.6 17.2 19.4 21.7 22.8
Outdoor temperature
°CDB
TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP TC SHC IP
kW kW kW kW kW kW
-20.6 5.60 3.36 0.30 6.24 3.37 0.30 6.88 3.68 0.31 7.09 3.97 0.31 7.51 3.96 0.32 7.95 4.22 0.32
-15.0 5.60 3.36 0.37 6.24 3.38 0.38 6.88 3.69 0.38 7.08 3.98 0.39 7.51 3.97 0.39 7.94 4.23 0.39
-10.0 5.59 3.33 0.45 6.22 3.35 0.45 6.86 3.65 0.46 7.07 3.94 0.46 7.49 3.93 0.47 7.93 4.19 0.47
-5.0 5.59 3.40 0.52 6.21 3.42 0.52 6.86 3.73 0.53 7.07 4.02 0.54 7.49 4.00 0.54 7.92 4.27 0.54
0.0 5.58 3.46 0.59 6.21 3.48 0.60 6.86 3.80 0.60 7.07 4.10 0.61 7.48 4.08 0.61 7.91 4.36 0.62
5.0 5.58 3.33 0.65 6.21 3.35 0.66 6.85 3.65 0.67 7.07 3.94 0.68 7.48 3.92 0.68 7.91 4.18 0.69
10.0 5.56 3.39 0.74 6.19 3.42 0.75 6.83 3.73 0.76 7.04 4.02 0.77 7.46 4.00 0.77 7.89 4.27 0.78
15.0 5.46 3.32 0.82 6.08 3.34 0.83 6.70 3.64 0.84 6.91 3.93 0.85 7.32 3.91 0.85 7.74 4.17 0.86
19.4 5.25 3.24 0.95 5.85 3.26 0.97 6.44 3.56 0.98 6.64 3.84 0.99 7.04 3.83 1.00 7.44 4.08 1.01
25.0 5.66 3.39 1.37 6.30 3.41 1.39 6.95 3.72 1.41 7.16 4.02 1.42 7.59 4.00 1.43 8.02 4.26 1.44
30.6 5.38 3.29 1.53 6.00 3.31 1.55 6.61 3.61 1.58 6.82 3.90 1.58 7.22 3.88 1.60 7.63 4.14 1.61
35.0 5.09 3.19 1.70 5.67 3.20 1.72 6.25 3.50 1.75 6.44 3.77 1.76 6.83 3.76 1.78 7.21 4.00 1.80
40.0 4.76 3.07 1.86 5.30 3.09 1.89 5.84 3.37 1.92 6.02 3.64 1.93 6.38 3.62 1.95 6.74 3.86 1.97
46.1 3.62 2.70 1.56 4.03 2.72 1.58 4.45 2.97 1.61 4.58 3.20 1.61 4.86 3.19 1.63 5.13 3.40 1.65