NO
OK
NO
Setting DescriptionFunction Number
Setting Value
Standard insulation
95
00
01
High insulation
Too Cool
Trouble shooting 37
Forecast of Cause
Check Point 1-1 : Check Function Setting
If insulation level is greater than R-13 set function 95 to 01.
Ref.)
Using the table on the right adjust function 30.
(Room Temperature Control for indoor unit sensor)
Check Point 4 : Check Function Settings
Check Point 3 : Check the remote controller display
Check Point 2 : Verfity room temperature sensing location
“Indoor unit sensor”
“Wired remote sensor”
Do you want room temperature sensed at the
wired remote controller (Wired remote sensor) or
by they build in sensor inside the unit (Indoor unit sensor).
Check Point 1-2 : Check effects of Function Setting change
Is the space still too cool in relation to set point.
Too cool
TO NEXT PAGE
Is the "Thermo Sensor Icon" displayed on the screen?
Check Point 3-1 : Check the remote controller
Hold down the THERMO SENSOR button until
the thermo sensor icon is turned off.
Setting DescriptionFunction Number Setting Value
Standard setting
No correction 0.0°F (0.0°C)
00
01
10
11
12
13
14
15
16
17
30
(For
cooling)
Less
Cooling
Ref.)
+1°F (+0.5°C)
+2°F (+1.0°C)
+4°F (+2.0°C)
+3°F (+1.5°C)
+5°F (+2.5°C)
+6°F (+3.0°C)
+7°F (+3.5°C)
+8°F (+4.0°C)
1. House insulation setting has not been changed.
2. Temperature sensing location has not been changed.
3. Installation location of the wired remote.
4. Function settings have not been changed.
YES
YES
Is insulation level greater than R-13.
Check Point 1 : Check insulation level of structure
of house
Too cool
02-42