5. INDOOR FAN CONTROL
The airflow can be switched in 5 steps such as Auto, Quiet, Low, Med, High,
while the indoor fan only runs.
When fan mode is set at [Auto], it operates on [Med] fan Speed.
01-04
2. FAN OPERATION
3. COOLING OPERATION
Switch the airflow [Auto], and the indoor fan motor will run according to a room temperature,
as shown in Fig. 4.
On the other hand, if switched in [High] [Quiet], the indoor motor will run at a constant airflow of [Cool]
operation modes Quiet, Low, Med, High, as shown in Table 5.
( Fig. 4 : Airflow change - over ( Cooling : Auto ) )
1. Fan speed
( Table 5 : Indoor fan speed )
Operation mode Air flow mode
Speed (rpm)
Cooling/ Fan
Heating
Dry
X zone: 960
J zone: 960
X zone: 1030
J zone: 1030
X zone: 1140
J zone: 1140
ARU9RLF ARU12RLF ARU18RLF
4. DRY OPERATION
Refer to the Table 5.
During the dry mode operation, the fan speed setting can not be changed.
High
High
Med
Med
Low
Low
Quiet
Quiet
S-Low
1260
1160
1060
960
500
1340
1240
1140
1030
500
1380
1300
1220
1140
600
1260
1160
1060
960
500
1340
1240
1140
1030
500
1380
1300
1220
1140
600
When the room
temperature rises
When the room
temperature drops
TR : Room temperature
Ts : Setting temperature
TR-Ts > 4°F
(2°C)
2°F > TR-Ts
(1°C)
4°F > TR-Ts > 2°F
(2°C) (1°C)
=
TR-Ts > 5°F
(2.5°C)
=
3°F > TR-Ts
(1.5°C)
5°F > TR-Ts > 3°F
(2.5°C) (1.5°C)
=
High mode
Med mode
Low mode
S-Low

Other manuals for Fujitsu AOU9RLFC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOU9RLFC and is the answer not in the manual?

Fujitsu AOU9RLFC Specifications

General IconGeneral
BrandFujitsu
ModelAOU9RLFC
CategoryAir Conditioner
LanguageEnglish

Related product manuals