EasyManua.ls Logo

Fujitsu AOUH24LMAS1 - Page 7

Fujitsu AOUH24LMAS1
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Type
Wall mounted
Inverter heat pump
Model name ASUH18LMAS ASUH24LMAS
NOTES:
Specifications are based on the following conditions:
Cooling: Indoor temperature of 80°FDB (26.67°CDB) /67°FWB (19.44°CWB), and outdoor temperature of 95°FDB (35°CDB) / 75°FWB (23.9°CWB).
Heating: Indoor temperature of 70°FDB (21.11°CDB) /59°FWB (15.56°CWB), and outdoor temperature of 47°FDB (8.33°CDB) /43°FWB (6.11°CWB).
*
1
: Heating (17°F): Indoor temperature of 70°FDB (21.11°CDB) /60°FWB (15.56°CWB), and outdoor temperature of 17°FDB (-8.33°CDB) /15°FWB (-9.44°CWB).
Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
Protective function might work when using it outside the operation range.
*
2
: Maximum current is maximum value when operated within the operation range.
*
3
: Sound pressure level:
Measured values in manufacturer’s anechoic chamber.
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
*
4
: Available on Google Play
store or on App Store
®
. Optional WLAN adapter is also required. For details, refer to the setting manual.
- 3 -
1. Specifications
WALL MOUNTED
ASUH18-24LMAS
WALL MOUNTED
ASUH18-24LMAS

Table of Contents

Other manuals for Fujitsu AOUH24LMAS1

Related product manuals