EasyManuals Logo

Fujitsu AOY14LFBC User Manual

Fujitsu AOY14LFBC
83 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
2. HEATING OPERATION
2-1 HEATING CAPACITY CONTROL
A sensor (room temperature thermistor) built in the indoor unit body will usually perceive
difference or variation between a set temperature and present room temperature, and
controls the operation frequency of the compressor.
* If the room temperature is lower by 3 C than a set temperature, the compressor operation
frequency will attain to maximum performance.
* If the room temperature is higher 2.5 C than a set temperatire, the compressor will be
stopped.
minimum
frequency
maximum
frequency
AS*9LSACW 18Hz 130Hz
AS*12LSACW 18Hz 130Hz
AS*9LSBCW 18Hz 130Hz
AS*12LSBCW 18Hz 130Hz
AS*14LSBCW 18Hz 119Hz
AS*18LSBCW 18Hz 119Hz
Outside air Outside air
temperature temperature
19 C
C zone
17 C
14 C
B zone
12 C
A zone
Hi Me Lo Quiet
A zone 130Hz 92Hz 80Hz 68Hz
B zone 130Hz 80Hz 60Hz 54Hz
9LSACW
C zone 96Hz 68Hz 54Hz 51Hz
A zone 130Hz 96Hz 80Hz 68Hz
B zone 130Hz 96Hz 64Hz 57Hz
12LSACW
C zone 96Hz 96Hz 64Hz 54Hz
A zone 130Hz 96Hz 80Hz 68Hz
B zone 130Hz 96Hz 80Hz 54Hz
9LSBCW
C zone 130Hz 96Hz 80Hz 45Hz
A zone 130Hz 96Hz 80Hz 68Hz
B zone 130Hz 96Hz 80Hz 54Hz
12LSBCW
C zone 130Hz 96Hz 80Hz 45Hz
A zone 119Hz 90Hz 70Hz 58Hz
B zone 119Hz 90Hz 70Hz 58Hz
14LSBCW
C zone 119Hz 90Hz 70Hz 58Hz
A zone 119Hz 90Hz 70Hz 58Hz
B zone 119Hz 90Hz 70Hz 58Hz
18LSBCW
C zone 119Hz 90Hz 70Hz 58Hz
* When the room temperature is between +2 C to -3 C of the setting temperature,
the compressor frequency is controlled within the range shown in Table2.
However, the maximum frequency is limited in the range shown in Figure 2 based on the
fan speed mode and the outdoor temperature.
( Table 2 : Compressor Frequency Range )
( Fig.2 : Limit of Maximum Frequency based on Outdoor Temperature )
* The room temperature is controlled 2 C higher than the setting temperature for 60 minutes
after starting the operation.
After 60 minutes, it is controlled based on the normal setting temperature.
05-02

Table of Contents

Other manuals for Fujitsu AOY14LFBC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOY14LFBC and is the answer not in the manual?

Fujitsu AOY14LFBC Specifications

General IconGeneral
BrandFujitsu
ModelAOY14LFBC
CategoryAir Conditioner
LanguageEnglish

Related product manuals