EasyManua.ls Logo

Fujitsu AOY9FSBC - Installation and Preparation; Power Connection Procedures; Remote Controller Setup

Fujitsu AOY9FSBC
17 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-Way valve
(with charging port)
Condenser
Dryer
Capillary tube
2-Way valve
(Flare connection)
Gas pipe (9.52 dia.)
(Flare connection)
(Flare connection)
Liquid pipe (6.35 dia.)
(Flare connection)
[ INDOOR UNIT ]
[ OUTDOOR UNIT ]
[ Connecting pipe ]
Evaporator
Com-
pressor
REFRIGERANT SYSTEM DIAGRAM
Models : ASY9FSBCW / AOY9FSBC
3-Way valve
(with charging port)
Condenser
Dryer
Capillary tube
2-Way valve
(Flare connection)
Gas pipe (9.52 dia.)
(Flare connection)
(Flare connection)
Liquid pipe (6.35 dia.)
(Flare connection)
[ INDOOR UNIT ]
[ OUTDOOR UNIT ]
[ Connecting pipe ]
Evaporator
Com-
pressor
Models : ASY12FSBCW / AOY12FSBC
2003.10.30 4