EasyManua.ls Logo

Fujitsu AOYG12KETA - External Output

Fujitsu AOYG12KETA
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8-2. External output
Use an external output cable with appropriate external dimension, depending on the number of ca-
bles to be installed.
¢
External input and output PCB
A twisted pair cable (22AWG) should be used. Maximum length of cable is 25 m.
Output voltage: High DC 12 V±2 V, Low 0 V.
Permissible current: 50 mA
For details, refer to "Combination of external input and output" on page 23.
When indicator or other components are connected directly:
Example: Rotary SW on External input and output PCB is set to “1”.
1
2
Connector
(CN310)
LED 1
(Operation status)
PCB
Resistor
Connected unit
+
-
1
2
Connector
(CN311)
LED 2
(Error status)
Resistor
+
-
1
2
Connector
(CN312)
LED 3
(Indoor unit fan
operation status)
Resistor
+
-
When connecting with a device equipped with a power supply:
Example: Rotary SW on External input and output PCB is set to “1”.
1
2
Connected device 1
Connector
(CN310)
PCBConnected unit
Relay
(Operation status)
-
+
1
2
Connected device 2
Connector
(CN311)
(Error status)
-
+
1
2
Connected device 3
Connector
(CN312)
(Indoor unit fan
operation status)
-
+
- 22 -
8-2. External output 8. External input and output
WALL MOUNTED
ASYG07-14KETA
WALL MOUNTED
ASYG07-14KETA

Table of Contents