4-2. Heating capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
¢
Model: ASYG07KGTE
AFR
m
3
/h
720
Indoor temperature
16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 3.08 1.30 3.11 1.35 3.09 1.38 3.06 1.42 3.04 1.43
-10 -11 3.62 1.39 3.66 1.44 3.63 1.46 3.60 1.51 3.58 1.52
-5 -7 4.10 1.44 4.13 1.49 4.10 1.52 4.06 1.56 4.04 1.57
0 -2 4.50 1.48 4.54 1.53 4.43 1.53 4.36 1.56 4.35 1.59
5 3 4.86 1.45 4.94 1.51 4.82 1.51 4.74 1.55 4.73 1.57
7 6 5.24 1.48 5.33 1.58 5.20 1.58 5.12 1.62 5.11 1.64
10 8 5.39 1.51 5.49 1.61 5.28 1.59 5.27 1.65 5.26 1.67
15 10 5.29 1.31 5.38 1.40 5.16 1.40 5.17 1.43 5.16 1.45
20 15 5.54 1.25 5.54 1.23 5.38 1.24 5.26 1.23 5.11 1.25
24 18 5.69 1.18 5.69 1.17 5.53 1.17 5.40 1.16 5.26 1.18
¢
Model: ASYG09KGTE
AFR
m
3
/h
750
Indoor temperature
16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 3.20 1.42 3.23 1.47 3.21 1.50 3.18 1.54 3.16 1.55
-10 -11 3.76 1.51 3.80 1.57 3.77 1.59 3.74 1.64 3.72 1.65
-5 -7 4.26 1.56 4.29 1.62 4.26 1.65 4.22 1.70 4.19 1.71
0 -2 4.67 1.61 4.72 1.67 4.61 1.66 4.53 1.70 4.52 1.73
5 3 5.04 1.58 5.13 1.65 5.01 1.65 4.93 1.68 4.92 1.71
7 6 5.44 1.61 5.53 1.72 5.40 1.72 5.31 1.76 5.30 1.79
10 8 5.60 1.64 5.70 1.76 5.48 1.73 5.47 1.79 5.46 1.82
15 10 5.49 1.42 5.59 1.52 5.36 1.52 5.37 1.55 5.35 1.58
20 15 5.75 1.36 5.75 1.34 5.58 1.35 5.46 1.34 5.31 1.36
24 18 5.91 1.29 5.91 1.27 5.74 1.28 5.61 1.27 5.46 1.29
¢
Model: ASYG12KGTE
AFR
m
3
/h
770
Indoor temperature
16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 3.40 1.39 3.39 1.36 3.36 1.36 3.34 1.37 3.30 1.40
-10 -11 4.02 1.41 3.93 1.43 3.83 1.46 3.72 1.48 3.60 1.52
-5 -7 4.60 1.51 4.50 1.54 4.39 1.57 4.26 1.60 4.12 1.63
0 -2 5.29 1.63 5.17 1.66 5.04 1.69 4.89 1.72 4.73 1.76
5 3 6.06 1.77 5.93 1.79 5.78 1.83 5.61 1.87 5.43 1.91
7 6 6.40 1.82 6.26 1.85 6.10 1.89 5.92 1.93 5.73 1.97
10 8 6.94 1.92 6.78 1.94 6.61 1.98 6.42 2.02 6.21 2.07
15 10 6.33 1.58 6.19 1.60 6.03 1.63 5.86 1.66 5.67 1.70
20 15 6.61 1.38 6.46 1.41 6.29 1.43 6.11 1.46 5.91 1.50
24 18 6.89 1.32 6.75 1.40 6.50 1.37 6.14 1.36 5.66 1.39
¢
Model: ASYG14KGTE
AFR
m
3
/h
800
Indoor temperature
16 18 20 22 24
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP TC IP
kW kW kW kW kW
-15 -16 3.57 1.51 3.56 1.49 3.52 1.48 3.51 1.50 3.46 1.53
-10 -11 4.22 1.53 4.12 1.56 4.02 1.59 3.90 1.62 3.77 1.66
-5 -7 4.83 1.65 4.72 1.67 4.60 1.71 4.47 1.74 4.33 1.78
0 -2 5.55 1.78 5.42 1.81 5.29 1.84 5.13 1.88 4.97 1.92
5 3 6.36 1.93 6.22 1.96 6.06 1.99 5.89 2.03 5.70 2.08
7 6 6.72 1.99 6.57 2.02 6.40 2.06 6.21 2.10 6.01 2.15
10 8 7.28 2.09 7.11 2.12 6.93 2.16 6.73 2.20 6.52 2.26
15 10 6.64 1.72 6.49 1.74 6.33 1.78 6.15 1.81 5.95 1.86
20 15 6.93 1.51 6.77 1.53 6.60 1.56 6.41 1.59 6.20 1.63
24 18 7.22 1.44 7.08 1.53 6.82 1.50 6.44 1.48 5.94 1.52