8-5. Details of control output function
¢
Operation status
Function
setting
External input and
output PCB
External output Output signal Status
Rotary switch
60-00 1, 2 Output of indoor unit CN47
Off → On Operation
On → Off Stop
— 1, B, C
External input and
output PCB
CN310
Off → On Operation
On → Off Stop
The output is low when the unit is stopped.
On
Off
On
Off
CN47
On
Off
CN310
Indoor unit operation
¢
Error status
Function
setting
External input and
output PCB
External output Output signal Status
Rotary switch
60-09 — Output of indoor unit CN47
Off → On Error
On → Off Normal
— 2
External input and
output PCB
CN310
Off → On Error
On → Off Normal
— 1, C
External input and
output PCB
CN311
Off → On Error
On → Off Normal
The output is on when an error is generated for the indoor unit.
Error
Normal
On
Off
CN47
On
Off
CN310, 311, 312
Indoor unit
- 31 -
8-5. Details of control output function
8. External input and output
WALL MOUNTED
ASYG07-14KGT
WALL MOUNTED
ASYG07-14KGT