SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED
type
Models Indoor unit Outdoor unit
ASYA07LCC
ASYA09LCC
ASYA12LCC
ASYA14LCC
ASYA18LCC
ASYB09LDC
ASYB12LDC
AOYR07LCC
AOYR09LCC
AOYR12LCC
AOYR14LCC
AOYR18LCC
AOYS09LDC
AOYS12LDC
INVERTER
SERVICE
INSTRUCTION
R410A

Other manuals for Fujitsu AOYR12LCC

Questions and Answers:

Fujitsu AOYR12LCC Specifications

General IconGeneral
BrandFujitsu
ModelAOYR12LCC
CategoryAir Conditioner
LanguageEnglish

Summary

Specifications

Dimensions

Refrigerant System Diagram

Circuit Diagram

Description of Each Control Operation

Cooling Operation

Details compressor frequency control based on room and outdoor temperature.

Heating Operation

Explains compressor frequency control during heating based on room and outdoor temperature.

Dry Operation

Describes compressor frequency and indoor fan control during dry mode.

Auto Changeover Operation

Details automatic switching between modes based on temperature zones.

Indoor Fan Control

Explains fan speed settings and operation modes for the indoor fan.

Outdoor Fan Control

Describes outdoor fan motor types and speed control based on conditions.

Louver Control

Details vertical louver adjustment and swing operation for airflow direction.

Compressor Control

Explains compressor operation frequency ranges and startup control.

Timer Operation Control

Describes ON/OFF timers, program timer, and sleep timer functions.

Electronic Expansion Valve Control

Explains how the electronic expansion valve opening is calculated and controlled.

Test Operation Control

Details how to enter and conduct test operation mode for troubleshooting.

Prevent to Restart for 3 Minutes (3 Minutes ST)

Specifies the delay before the compressor can restart after stopping.

Four-Way Valve Extension Select

Describes the switching of the four-way valve between cooling and heating modes.

Auto Restart

Explains how operation contents are memorized and restored after a power failure.

Manual Auto Operation

Details the operation controlled by the MANUAL AUTO button without a remote.

Forced Cooling Operation

Explains how to initiate forced cooling operation using the manual button.

Compressor Preheating

Describes the preheating process for the compressor in heating mode.

Coil Dry Operation Control

Details the coil-dry operation cycles and fan operation.

Defrost Operation Control

Explains the conditions for starting and completing defrost operation.

Off Defrost Operation Control

Describes automatic defrosting when operation stops in heating mode.

Various Protections

Covers protections like discharge gas temperature, current release, and anti-freezing.

Refrigerant Caution -R410A

R410A Tools

Lists and describes specialized tools required for R410A systems.

Precaution for Installation

Provides essential precautions for installing units with R410A refrigerant.

Precaution for Servicing

Outlines precautions for servicing, focusing on refrigerant oil and pressure differences.

New Refrigerant R410A

Discusses R410A as a new refrigerant and its phase-out schedule.

Differences from Conventional Model (R22) and Precautions

Compares R410A with R22, highlighting differences in oil, compressor, and parts.

Trouble Shooting

Unit Does Not Operate (No Lights)

Provides troubleshooting steps for a unit that shows no power indication.

Self-Diagnosis Function

Explains how to use the self-diagnosis function and interpret error indications.

Serial Signal Receiving Error

Details troubleshooting for errors related to indoor/outdoor unit communication.

IPM Protection Troubleshooting

Provides steps to diagnose and resolve IPM protection issues in the outdoor unit.

Refrigerant Cycle Troubleshooting

Offers a diagnostic table and methods for refrigerant cycle related problems.

Appending Data

Jumper Setting

Details indoor and outdoor unit jumper settings for various functions.

Outdoor Unit Pressure and Current Curves (Cooling)

Presents cooling curves for outdoor unit low pressure and total electric current.

Outdoor Unit Pressure and Current Curves (Heating)

Presents heating curves for outdoor unit high pressure and total electric current.

Outdoor Unit Pressure and Current Curves (Cooling) - ASYB Models

Shows cooling curves for ASYB models' outdoor unit pressure and current.

Outdoor Unit Pressure and Current Curves (Heating) - ASYB Models

Shows heating curves for ASYB models' outdoor unit pressure and current.

Outdoor Unit Pressure and Current Curves (Cooling) - ASYA14/18LCC

Presents cooling curves for ASYA14/18LCC outdoor unit pressure and current.

Outdoor Unit Pressure and Current Curves (Heating) - ASYA14/18LCC

Shows heating curves for ASYA14/18LCC outdoor unit pressure and current.

Thermistor Resistance Values

Provides tables and charts of resistance values for various thermistors.

Capacity/Input Data (ASYA09LCC Heating)

Shows heating capacity and input data graphs for ASYA09LCC.

Capacity/Input Data (ASYA09LCC Cooling)

Shows cooling capacity and input data graphs for ASYA09LCC.

Capacity/Input Data (ASYA12LCC Heating)

Shows heating capacity and input data graphs for ASYA12LCC.

Capacity/Input Data (ASYA12LCC Cooling)

Shows cooling capacity and input data graphs for ASYA12LCC.

Capacity/Input Data (ASYA18LCC Heating)

Shows heating capacity and input data graphs for ASYA18LCC.

Capacity/Input Data (ASYA18LCC Cooling)

Shows cooling capacity and input data graphs for ASYA18LCC.

Capacity/Input Data (ASYB09LDC Heating)

Shows heating capacity and input data graphs for ASYB09LDC.

Capacity/Input Data (ASYB09LDC Cooling)

Shows cooling capacity and input data graphs for ASYB09LDC.

Capacity/Input Data (ASYB12LDC Heating)

Shows heating capacity and input data graphs for ASYB12LDC.

Capacity/Input Data (ASYB12LDC Cooling)

Shows cooling capacity and input data graphs for ASYB12LDC.

Replacement Parts

Installation Manual

Selecting the Mounting Position

Guides on choosing optimal locations for indoor and outdoor units.

Indoor Unit Piping Direction

Explains the five possible directions for connecting indoor unit piping.

Installation Diagram of Indoor and Outdoor Units

Illustrates the required clearances and placement for unit installation.

Front Panel and Intake Grille Removal/Installation

Instructions for removing and installing the indoor unit's front panel and intake grille.

Pump Down Operation (Forced Cooling)

Procedure for recovering refrigerant before unit relocation or disposal.

Air Purge Process

Steps for purging air from the refrigerant circuit using a vacuum pump.

Connecting the Piping

Details on flaring, connecting pipes, and tightening flare nuts.

Test Running Procedure

Steps for performing a test run to verify proper operation after installation.