SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED
type
Models Indoor unit Outdoor unit
ASYA07LCC
ASYA09LCC
ASYA12LCC
ASYA14LCC
ASYA18LCC
ASYB09LDC
ASYB12LDC
AOYR07LCC
AOYR09LCC
AOYR12LCC
AOYR14LCC
AOYR18LCC
AOYS09LDC
AOYS12LDC
INVERTER
SERVICE
INSTRUCTION
R410A

Other manuals for Fujitsu AOYR09LCC

Questions and Answers

  • L
    lbradleySep 4, 2025
    What does serial reverse transfer error during the operation mean for Fujitsu AOYR09LCC?
    • R
      Robert DrakeSep 4, 2025
      If your Fujitsu Air Conditioner displays a serial reverse transfer error during operation, it means the indoor unit isn't receiving a signal for 10 seconds. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • B
    Brian BeckSep 18, 2025
    Why Fujitsu AOYR09LCC Air Conditioner has power supply frequency detection error?
    • S
      Samantha AndersonSep 18, 2025
      If your Fujitsu Air Conditioner displays a power supply frequency detection error, it means the power supply frequency cannot be recognized after 4 seconds of power ON. The Controller PCB might be defective.
  • K
    Kevin BaileySep 16, 2025
    What does forced auto switch error mean on Fujitsu AOYR09LCC?
    • S
      Susan AlvaradoSep 16, 2025
      If your Fujitsu Air Conditioner displays a forced auto switch error, it means the forced auto switch has been ON for 30 consecutive seconds. Check if the forced auto switch is kept pressed. The forced auto switch might be defective or the Controller PCB might be defective.
  • J
    Joan HaynesSep 14, 2025
    What to do if my Fujitsu AOYR09LCC Air Conditioner shows outdoor temperature thermistor error?
    • W
      wongmarySep 15, 2025
      If your Fujitsu Air Conditioner displays an outdoor temperature thermistor error, it means the detection value of the outdoor temperature thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • J
    Jeffrey JenkinsSep 12, 2025
    What does outdoor heat exchanger thermistor error mean for Fujitsu Air Conditioner?
    • J
      Jason YoungSep 13, 2025
      If your Fujitsu Air Conditioner displays an outdoor heat exchanger thermistor error, it means the detection value of the outdoor heat exchanger thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • T
    Tanya AtkinsSep 12, 2025
    What to do if my Fujitsu AOYR09LCC shows discharge thermistor error?
    • T
      Timothy MclaughlinSep 12, 2025
      If your Fujitsu Air Conditioner displays a discharge thermistor error, it means the detection value of the discharge thermistor is either open or shorted. Check the thermistor resistance value. The controller PCB might be defective.
  • J
    jamiekirkSep 9, 2025
    What causes Indoor heat exchanger thermistor error in Fujitsu AOYR09LCC Air Conditioner?
    • R
      Robert MartinezSep 9, 2025
      If your Fujitsu Air Conditioner shows an indoor heat exchanger thermistor error, it means the detection value of the indoor heat exchanger thermistor is either open or shorted when the power is ON. Check the thermistor resistance value. The controller PCB might be defective.
  • D
    donna46Sep 7, 2025
    What does serial forward transfer error during the operation mean for Fujitsu AOYR09LCC Air Conditioner?
    • H
      Heather LewisSep 7, 2025
      If your Fujitsu Air Conditioner displays a serial forward transfer error during operation, it means the outdoor unit isn't receiving a signal for 10 seconds. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • J
    james05Sep 5, 2025
    Why Fujitsu Air Conditioner shows serial forward transfer error at starting up operation?
    • B
      Brenda HancockSep 6, 2025
      If your Fujitsu Air Conditioner displays a serial forward transfer error at startup, it means the outdoor unit isn't receiving a signal for 10 seconds after the power relay turns on. Check the indoor/outdoor cable connection. If the wiring is normal, measure the voltage of the outdoor unit terminals and diagnose the defective location.
  • J
    jane62Aug 21, 2025
    Why my Fujitsu AOYR09LCC Air Conditioner does not operate at all?
    • S
      Shawn DavisAug 21, 2025
      If your Fujitsu Air Conditioner isn't operating, and the Operation Lamp and Timer Lamp aren't lit, you should check a few things: * Ensure the input power voltage from the exclusive circuit AC outlet is normal. * Make sure the AC plug is securely inserted into the AC outlet and isn't loose. * Verify that any connected cables are wired correctly. * Confirm that each connector is securely inserted.

Summary

Specifications

Dimensions

Refrigerant System Diagram

Circuit Diagram

Description of Each Control Operation

1. Cooling Operation

Details the system's cooling process, including capacity control based on room and outdoor temperatures.

2. Heating Operation

Explains the heating mode operation, focusing on compressor frequency control.

3. Dry Operation

Describes the dry mode operation, detailing compressor and indoor fan control.

5. Indoor Fan Control

Covers indoor fan speed settings and operation modes for airflow control.

8. Compressor Control

Details compressor operation frequency ranges and start-up control.

19. Defrost Operation Control

Explains conditions for starting and completing defrost operations.

21. Various Protections

Outlines various protection mechanisms and their control parameters.

Refrigerant Caution -R410 A

R410 A Tools

Precaution for Installation

Precaution for Servicing

New Refrigerant R410 A

Difference from Conventional Model (R22) and Precautions

Trouble Shooting

1. Unit Does Not Operate (No Lamps Lit)

Troubleshooting steps for when the unit fails to power on, checking lamps and power supply.

2. Self Diagnosis Function

Explains blinking indicators for error detection and how to use the self-diagnosis feature.

3. Trouble Shooting Method

General methods for troubleshooting, including signal checks and cycle diagnosis.

Serial Signal Receiving Error

Diagnoses issues related to communication errors between indoor and outdoor units.

IPM Protection

Details checks for IPM protection faults, including compressor and PCB diagnostics.

Trouble Shooting of Refrigerant Cycle

Identifies common refrigerant cycle issues and their potential causes.

Appending Data

1. Jumper Setting of Indoor and Outdoor Units

Configuration settings for indoor and outdoor units using jumpers.

2. Outdoor Unit Pressure and Current Curves

Graphical data showing pressure and current variations with temperature.

3. Thermistor Resistance Values

Provides resistance values for various thermistors at different temperatures.

4. Capacity;Input Data

Presents capacity and input data charts for different operating conditions.

Replacement Parts

Replacement Parts

Illustrations showing exploded views of indoor and outdoor unit components.

Installation Manual

Standard Accessories

Lists the standard parts supplied with the air conditioner for installation.

Electrical Requirement

Specifies electrical connection requirements, including circuit and wiring.

Selecting the Mounting Position

Guidelines for choosing optimal locations for indoor and outdoor unit installation.

Installation Diagram of Indoor and Outdoor Units

Visual representation of unit placement and required clearances.

Front Panel Removal and Installation

Instructions for safely removing and reinstalling the unit's front panel.

Finishing

Details on insulating pipes, sealing gaps, and securing connections after installation.

Outdoor Unit Installation

Specific steps and precautions for installing the outdoor unit securely.

Air Purge

Procedure for removing air from the refrigerant system using a vacuum pump.

Test Running

Steps for performing operational checks after installation to ensure proper function.

Special Tools for R410 A

Lists and describes the specialized tools required for R410A refrigerant systems.

Fujitsu AOYR09LCC Specifications

General IconGeneral
Cooling Capacity2.5 kW
Heating Capacity3.2 kW
RefrigerantR32
Power Supply220-240V, 50Hz
Indoor Unit Weight9 kg
Indoor Unit Noise Level21 dB(A)