EasyManua.ls Logo

Fujitsu AOYR18LCC User Manual

Fujitsu AOYR18LCC
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED
type
Models Indoor unit Outdoor unit
ASYA07LCC
ASYA09LCC
ASYA12LCC
ASYA14LCC
ASYA18LCC
ASYB09LDC
ASYB12LDC
AOYR07LCC
AOYR09LCC
AOYR12LCC
AOYR14LCC
AOYR18LCC
AOYS09LDC
AOYS12LDC
INVERTER
SERVICE
INSTRUCTION
R410A

Other manuals for Fujitsu AOYR18LCC

Questions and Answers:

Fujitsu AOYR18LCC Specifications

General IconGeneral
BrandFujitsu
ModelAOYR18LCC
CategoryAir Conditioner
LanguageEnglish

Summary

Specifications

Specifications

Model details, electrical data, fan motor specs, dimensions, weights, noise, and pipe thickness.

Specifications

Continuation of specifications for various models.

Specifications

Continuation of specifications for various models.

Specifications

Continuation of specifications for various models.

Dimensions

Dimensions

Overall dimensions for indoor and outdoor units.

Dimensions

Continuation of dimensions for ASYA07/09LCC, AOYR07/09LCC.

Dimensions

Continuation of dimensions for ASYA12LCC, AOYR12LCC.

Dimensions

Continuation of dimensions for ASYB09/12LDC, AOYS09/12LDC.

Dimensions

Continuation of dimensions for ASYA14/18LCC, AOYR14/18LCC.

Refrigerant System Diagram

Refrigerant System Diagram

Diagrams illustrating the refrigerant flow for different model groups.

Refrigerant System Diagram

Diagram for ASYA07/09LCC, AOYR07/09LCC.

Refrigerant System Diagram

Diagram for ASYA12LCC, AOYR12LCC, ASYB09/12LDC, AOYS09/12LDC.

Refrigerant System Diagram

Diagram for ASYA14/18LCC, AOYR14/18LCC.

Circuit Diagram

Circuit Diagram

Electrical wiring diagrams for various model series.

Circuit Diagram

Diagram for ASYA07LCC / AOYR07LCC, ASYA09LCC / AOYR09LCC.

Circuit Diagram

Diagram for ASYA12LCC / AOYR12LCC.

Circuit Diagram

Diagram for ASYB09LDC / AOYS09LDC, ASYB12LDC / AOYS12LDC.

Circuit Diagram

Diagram for ASYA14LCC / AOYR14LCC, ASYA18LCC / AOYR18LCC.

Description of Control Operations

Cooling Operation

Controls compressor frequency based on room and outdoor temperatures for optimal cooling.

Heating Operation

Controls compressor frequency based on room and outdoor temperatures for optimal heating.

Dry Operation

Manages compressor frequency and indoor fan for dry operation mode.

Auto Changeover Operation

Automatically switches between modes based on temperature.

Indoor Fan Control

Details fan speed settings and operation for different modes.

Cool Air Prevention Control (Heating Mode)

Controls indoor fan speed to prevent cold air during heating mode.

Outdoor Fan Control

Louver Control

Compressor Control

Timer Operation Control

Sleep Timer

Adjusts set temperature automatically during sleep timer operation.

Operation Controls and Protections

Electronic Expansion Valve Control

Manages the electronic expansion valve opening based on system conditions.

Test Operation Control

Procedure for running the unit in a test mode for diagnostics.

Prevent to Restart for 3 Minutes

Safety feature preventing rapid compressor restarts.

Four-Way Valve Extension Select

Control logic for the four-way valve.

Auto Restart

Function to resume operation with previous settings after power interruption.

Additional Operation Modes

Manual Auto Operation (Indoor Unit)

Allows basic operation via indoor unit buttons when remote is unavailable.

Forced Cooling Operation

Initiates cooling operation regardless of room temperature for quick cooling.

Compressor Preheating

Heats the compressor to improve warm air discharge upon startup.

Coil Dry or Air Clean Operation Control

Controls for coil drying and air purification functions.

Defrost Operation Control

Defrost Flow Chart

Illustrates the conditions and sequence for defrost operation.

Off Defrost Operation Control

Various Protections

Antifreezing Control (Cooling and Dry Mode)

Prevents indoor heat exchanger freezing by adjusting compressor frequency.

Cooling Pressure Overrise Protection

Stops compressor if high pressure is detected during cooling.

High Temperature Release Control (Heating Mode)

Reduces compressor frequency based on indoor heat exchanger temperature in heating.

Refrigerant Caution -R410A

R410A Tools

Lists and describes specialized tools required for R410A refrigerant handling.

Precaution for Installation

Important considerations for installing systems with R410A refrigerant.

R410A Refrigerant Handling

Details proper procedures for handling moisture, air, refrigerant, and compressor oil.

Precaution for Servicing

Precautions for servicing units using new refrigerants compared to older ones.

New Refrigerant R410A

Information on R410A, its phase-out schedule, and HFC properties.

Refrigerant Characteristics Comparison

Explains ozone depletion, defines CFC/HCFC/HFC, and compares refrigerant properties.

R407C and R410A Characteristics Summary

Compares R407C and R410A, and provides R410A pressure/temperature data.

Difference from Conventional Model (R22) and Precautions

Trouble Shooting

Unit Does Not Operate

Troubleshooting guide for a unit that does not operate at all.

Self-Diagnosis Function

Explains the self-diagnosis function and how to read error indications.

Serial Signal Receiving Error

Procedures to diagnose and resolve serial signal receiving errors.

IPM Protection

Identifies causes and checks for IPM protection faults in the outdoor unit.

Trouble Shooting of Refrigerant Cycle

Diagnostic table and methods for refrigerant cycle related issues.

Appending Data

Jumper Setting

Instructions for setting indoor and outdoor unit jumper configurations.

Performance Curves

Presents cooling and heating performance data curves for specific models.

Performance Curves

Continuation of performance curves for heating mode.

Performance Curves

Continuation of performance curves for cooling mode.

Performance Curves

Continuation of performance curves for heating mode.

Performance Curves

Continuation of performance curves for cooling mode.

Performance Curves

Continuation of performance curves for heating mode.

Thermistor Resistance Values

Tables and graphs showing thermistor resistance versus temperature.

Capacity/Input Data Curves

Heating capacity and input data curves for ASYA09LCC.

Capacity/Input Data Curves

Cooling capacity and input data curves for ASYA09LCC.

Capacity/Input Data Curves

Heating capacity and input data curves for ASYA12LCC.

Capacity/Input Data Curves

Cooling capacity and input data curves for ASYA12LCC.

Capacity/Input Data Curves

Heating capacity and input data curves for ASYA18LCC.

Capacity/Input Data Curves

Cooling capacity and input data curves for ASYA18LCC.

Capacity/Input Data Curves

Heating capacity and input data curves for ASYB09LDC.

Capacity/Input Data Curves

Cooling capacity and input data curves for ASYB09LDC.

Capacity/Input Data Curves

Heating capacity and input data curves for ASYB12LDC.

Capacity/Input Data Curves

Cooling capacity and input data curves for ASYB12LDC.

Replacement Parts

Replacement Parts Diagrams

Exploded views of internal components for various models.

Replacement Parts Diagrams

Continuation of exploded views for indoor units.

Replacement Parts Diagrams

Continuation of exploded views for outdoor units.

Replacement Parts Diagrams

Continuation of exploded views for outdoor units.

Replacement Parts Diagrams

Continuation of exploded views for outdoor units.

Replacement Parts Diagrams

Continuation of exploded views for indoor units.

Replacement Parts Diagrams

Continuation of exploded views for indoor units.

Replacement Parts Diagrams

Continuation of exploded views for outdoor units.

Replacement Parts Diagrams

Continuation of exploded views for indoor units.

Replacement Parts Diagrams

Continuation of exploded views for indoor units.

Replacement Parts Diagrams

Continuation of exploded views for outdoor units.

Replacement Parts Diagrams

Continuation of exploded views for outdoor units.

Replacement Parts Diagrams

Continuation of exploded views for indoor units.

Replacement Parts Diagrams

Continuation of exploded views for indoor units.

Replacement Parts Diagrams

Continuation of exploded views for outdoor units.

Replacement Parts Diagrams

Wiring lead wire process for AOYR07/09LCC.

Replacement Parts Diagrams

Connection of leads to inverter assy for AOYR07/09LCC.

Replacement Parts Diagrams

Shaping of leads to inverter assy for AOYR07/09LCC.

Replacement Parts Diagrams

Cross-sectional views of lead wire routing.

Replacement Parts Diagrams

Attachment of inverter assy for AOYR14/18LCC.

Replacement Parts Diagrams

Lead connections to inverter assy for AOYR14/18LCC.

Replacement Parts Diagrams

Lead routing for inverter assy for AOYR14/18LCC.

Replacement Parts Diagrams

Lead fixing for thermistor and motor for AOYR14/18LCC.

Installation Manual

General Installation Precautions and Electrical Requirements

Essential guidelines, electrical needs, and mounting position guidelines for installation.

Standard Accessories

Lists standard parts supplied with the unit for installation.

Selecting the Mounting Position

Guidelines for choosing optimal indoor and outdoor unit locations.

Indoor Unit Installation Procedures

Detailed steps for installing the indoor unit, including bracket mounting.

Outdoor Unit Installation Procedures

Detailed steps for installing the outdoor unit, including mounting and securing.

Piping and Wiring Procedures

Steps for connecting pipes, hoses, wiring, and finishing the installation.

Test Running

Steps to verify correct operation after installation.

R410A Installation Requirements

Covers general warnings, specialized tools, and copper pipe specifications for R410A.

Air Purge and Vacuuming

Procedures to remove air from the refrigerant system using a vacuum pump.

Related product manuals