Page #2 background imageLoading...
Page #2 background image
H x W x DOUTDOOR UNIT
DIMENSIONS
Shipping / NetOUTDOOR UNIT
WEIGHT
POWER SOURCE
Cooling
RUNNING CURRENT
Heating
INPUT WATTS
Cooling
Heating
EER
COP
Cooling
Heating
MOISTURE REMOVAL
AIR CIRCULATION, Outdoor
FAN MOTOR
INDOOR UNIT, Discrimination
High
INDOOR UNIT
Medium
Low
Upper fan
Lower fan
OUTDOOR UNIT, Discrimination
OUTDOOR UNIT
TYPE
Cooling & Heating
INDOOR UNIT
OUTDOOR UNIT
ARTG36LHTB
AOTG36LATT
COOLING CAPACITY
HEATING CAPACITY
INDOOR UNIT H x W x D 400 x 1,050 x 500 mm
1,290 x 900 x 330 mm
INDOOR UNIT
Shipping / Net
46 kg / 39 kg
113 kg / 104 kg
4.6 A
4.8 A
3.18 kW
3.30 kW
3.33 kW/kW
3.67 kW/kW
1.5 L/h
MAXIMUM CURRENT 9.0 A
AIR CIRCULATION, Indoor
2,500 m3/h
6,200 m3/h
415 V, 50 Hz, 3 phase, 4 W
MFG-36AVN
990 r.p.m.
850 r.p.m.
700 r.p.m.
MFE-54VVT
750 r.p.m.
780 r.p.m.
10.5 kW
12.1 kW
ELECTRICAL DATA
TYPE
DISCRIMINATION
WEIGHT (with oil)
REFRIGERANT TYPE
R410A
Hermetic type, Inverter, 4 poles,
3 phase, DC motor, Twin Rotary
DA422A3F-29ZAD
23.0 kg
PRECHARGED REFRIGERANT
3,450 g
COMPRESSOR AND REFRIGERANT
2012.05.08 1
SPECIFICATIONS
MAX PIPE HEIGHT 30 m
Pipe length
30 m
3,450 g
FULL CHARGE
45 m
4,200 g
60 m
4,950 g
75 m
5,700 g
ADDITIONAL CHARGE
50 g/m
NOISE LEVEL
High
INDOOR UNIT
Medium
Low
Cooling
Heating
41 dB
38 dB
36 dB
OUTDOOR UNIT
51 dB
53 dB

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ARTG36LHTB and is the answer not in the manual?

Fujitsu ARTG36LHTB Specifications

General IconGeneral
BrandFujitsu
ModelARTG36LHTB
CategoryAir Conditioner
LanguageEnglish

Related product manuals