SPLIT TYPE
ROOM AIR CONDITIONER
Models Indoor unit Outdoor unit
AOU36RLXFZH
AOU45RLXFZ
INVERTER MULTI
SERVICE
INSTRUCTION
R410A
Compact Wall Mounted
Wall Mounted / Floor
Compact Cassette / Slim Duct
ARU7RLF
ARU9RLF
ARU12RLF
ARU18RLF
ARU24RLF
AUU7RLF
AUU9RLF
AUU12RLF
AUU18RLF
ASU18RLF
ASU7RLF1
ASU9RLF1
ASU12RLF1
AGU9RLF
AGU12RLF
AGU15RLF
ASU24RLF

Table of Contents

Other manuals for Fujitsu ARU18RLF

Questions and Answers

  • E
    Elizabeth DavisAug 12, 2025
    What to do if my Fujitsu ARU18RLF Air Conditioner remote is not working due to a communication error?
    • T
      Trevor CampbellAug 13, 2025
      If you're experiencing a Wired Remote Controller Communication Error with your Fujitsu Air Conditioner, check the voltage. If it's DC12V, the remote control has failed and should be replaced. If it's DC 0V, the Controller PCB has failed and should be replaced after rechecking the remote control.
  • A
    Alexandra FisherAug 16, 2025
    What to do if my Fujitsu ARU18RLF has a drainage error?
    • X
      xburgessAug 16, 2025
      If your Fujitsu Air Conditioner is experiencing drainage issues, start by inspecting the float switch for proper operation using a meter to check its on/off switching. If the float switch is defective, replace it. Also, examine the drain hose for any clogs and clear them if necessary. If these steps don't resolve the issue, consider replacing the controller PCB.
  • H
    Heather DicksonAug 20, 2025
    How to fix a Fujitsu ARU18RLF indoor unit fan motor error?
    • J
      Jennifer TerryAug 20, 2025
      If you're encountering an indoor unit fan motor error with your Fujitsu Air Conditioner, check first the fan and bearing. If either is damaged, replace them. If the motor itself is faulty, replace the indoor unit fan motor. If these steps do not resolve the issue, replace the controller PCB.
  • A
    Alan KerrAug 25, 2025
    What to do if my Fujitsu ARU18RLF shows an indoor room thermistor error?
    • S
      Steven VelasquezAug 25, 2025
      If your Fujitsu Air Conditioner displays an indoor room thermistor error, begin by checking the connector to ensure it is securely attached and properly connected, and verify that the thermistor cable is not open. If the thermistor is either open or shorted, replace it and then reset the power.
  • K
    Kenneth RochaAug 27, 2025
    How to troubleshoot an Indoor Unit Model Information Error on my Fujitsu Air Conditioner?
    • J
      Jose HeathAug 28, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Model Information Error, check for external causes such as noise and ensure the ground connection is properly connected. Also, inspect all connectors for looseness or incorrect wiring, and check the PCB for any shorts or corrosion. If the problem persists, consider replacing the Controller PCB.
  • R
    Richard PageAug 31, 2025
    What does an Indoor Unit Capacity Error mean on my Fujitsu ARU18RLF?
    • C
      Christy NelsonAug 31, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Capacity Error, first verify the total capacity of the connected indoor units. If an abnormal condition is found, correct it by referring to the Installation Manual or Design & Technical Manual. If the problem persists, replace the Main PCB of the Outdoor unit.
  • I
    icrosbySep 4, 2025
    How to fix a Serial Communication Error (Serial Reverse Transfer Error) on a Fujitsu ARU18RLF?
    • A
      Abigail GarciaSep 4, 2025
      If your Fujitsu Air Conditioner displays a Serial Communication Error (Serial Reverse Transfer Error), check all connection lines between the indoor and outdoor units for any looseness or disconnections, referring to the Installation Manual or Data & Technical Manual for correction. Also, check the voltage of the power supply, ensuring it appears at the outdoor unit terminal L1 - L2 within the range of AC187V - 253V. Check that the indicated value swings between AC90V and AC270V at outdoor unit terminal 1 - 3. If the outdoor fan motor, active filter module, or IPM is abnormal, replace the corresponding part. If all parts are normal, replace the Main PCB.
  • C
    Cynthia Olson MDSep 8, 2025
    How to resolve a Damper (Open/Close) simultaneous detection Limit switch error on a Fujitsu Air Conditioner?
    • D
      Destiny MooreSep 8, 2025
      If your Fujitsu Air Conditioner displays a Damper(Open/Close) simultaneous detection Limit switch error, replace the limit switch if it is defective. If the problem persists, replace the Controller PCB.

Summary

Description of Each Control Operation

3. Indoor Fan Control

4. Louver Control

5. Outdoor Fan Control

6. Compressor Control

7. Timer Operation Control

8. Electronic Expansion Valve Control

19. Thermo Control (For Indoor Unit Sensor)

20. Thermo Control (For Wired Remote Sensor)

24. Drain Pump Operation

25. Air Outlet Selection (Damper Control )

26. Defrost Operation Control

27. Check Run Operation (Automatic Wiring Correction)

28. Various Protections

1. Discharge Gas Temperature Over Rise Prevention Control

Prevents compressor damage from high discharge gas temperature.

3. Cooling Pressure Over Rise Protection

Stops compressor if outdoor unit discharge pressure exceeds limits.

4. High Temperature Release Control (Heating mode)

5. High Pressure Protection

6. Compressor Temperature Protection

29. Pump Down Operation

30. Test Run (For Outdoor unit)

2. Trouble Shooting

2-1 Error Display

Lists error codes and their corresponding displays on indoor and remote controllers.

2-2 Trouble Shooting With Error Code

Provides step-by-step troubleshooting guides for various error codes.

2-3 Trouble Shooting With No Error Code

Offers troubleshooting steps for issues without specific error codes.

2-4 Service Parts Information

Service Parts Information 10

Procedures for replacing the Main PCB and related checks.