Heating mode
F zone
7°C
E zone
2°C
D zone
-7°C
C zone
B zone
A zone
-10°C
-15°C
G zone
12°C
H zone
16°C
I zone
20°C
Model name Outdoor temperature zone
Limitation of compressor
frequency
AOYG36KRTA
A zone 58 rps
B zone 52 rps
C zone 43 rps
D zone 38 rps
E zone 28 rps
F zone 23 rps
G zone 20 rps
H zone 17 rps
I zone 17 rps
AOYG45KRTA
A zone 46 rps
B zone 42 rps
C zone 35 rps
D zone 32 rps
E zone 23 rps
F zone 20 rps
G zone 17 rps
H zone 13 rps
I zone 16 rps
1-5. Compressor frequency limitation by outdoor temperature - (04-6) - 1. Compressor frequency control