¢ Cool air prevention control (heating mode)
The maximum value of the indoor fan speed is set as shown below, based on the detected tempera-
ture by the indoor heat exchanger sensor on heating mode.
Normal operation
Indoor heat exchanger
temperature rises
27°C
Stop
Setting fan mode
13 minutes later:
Indoor heat exchanger
temperature rises
27°C
LOW
Setting fan mode
10 °C HEAT operation
Indoor heat exchanger
temperature rises
27°C
LOW
AUTO