01-31
1-00. ERROR HISTORY MODE
1-26-4 ERROR CHECK MODE
•
In this mode, abnormality that is occurring now can be confirmed.
Confirm Chapter 2 " TROUBLE SHOOTING" in detail.
(Table : 26 Procedure for Error Check Mode )
Procedure Operation
Power
Mode
1
2
3
Check that the "ERROR" LED blinking (Hi-speed),
and then short press the ENTER SWITCH 1 time.
When reset of the ERROR history,
and then long press the MODE SWITCH.
Error code is displayed by lighting LED.
(Refer to Table : 27
)
: Light ON: Light OFF
2 : 2
Times Blinking
n : n Times Blinking
Error L1 L2 L6L5L4L3
2
n
Blinking
Hi-speed
n
DATA
2 2 2 2 2 2 2 2
After the error reset ,all LED is blinking and erased the all error history .
After this, ERROR LED is off and will normal display.
1 ~ : 1~ 15 Times Blinking 15
(Table : 28 Error Code)
: Light ON: Light OFF
2 : 2
Times Blinking
Combination error Indoor unit combination error