Trouble shooting 4
INDOOR UNIT Error Method:
External communication error
Detective Actuators:
Detective details:
Forecast of Cause :
OKOK
External communication error
Check any loose or removed connection of between the controller PCB to the external I/OPCB
>>If there is an abnormal condition, correct it by refer to installation manual or
the technical manual.
Check the condition condtion on the external I/O PCB and the controller PCB
(If there is loose connector, open cable or mis-wiring)
After receiving a signal from the external I/O PCB,
the same a signal has not been received for 15sec
1. Connection failure 2. External I/O PCB failure 3. Controller PCB failure
Check Point 1 : Check the connection
Check Point 2: Replace external I/O PCB
If Check Point 1 do not improve the symptom, change External I/O PCB.
OKOK
Check Point 3: Replace Controller PCB
If Check Point 2 do not improve the symptom, change Controller PCB.
Indicate or Display:
Error code : 18
02-05
Outdoor unit : No indication

Table of Contents

Other manuals for Fujitsu AS G07KGTB Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AS G07KGTB Series and is the answer not in the manual?

Fujitsu AS G07KGTB Series Specifications

General IconGeneral
BrandFujitsu
ModelAS G07KGTB Series
CategoryAir Conditioner
LanguageEnglish

Related product manuals