EasyManua.ls Logo

Fujitsu ASTG12KMCA User Manual

Fujitsu ASTG12KMCA
12 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
En-1PART No. 9333003016
AIR CONDITIONER
Wall Mounted Type
ASTG09KMCA
ASTG12KMCA
OPERATING MANUAL
Before using this product, read these instructions thoroughly and keep this manual for future reference.
Safety Precautions
To prevent personal injury, injury to others, or property damage, read this section carefully before you use this product, and be sure to comply to the
following safety precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classi ed as follows:
WARNING CAUTION
This mark warns of death or serious injury. This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED.
This mark denotes an action that is COMPULSORY.
Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING
This symbol shows that this appliance uses a ammable refrigerant. If the refrigerant is leaked and exposure to an external
ignition source, there is a risk of re.
CAUTION
This symbol shows that the Operation Manual should be read carefully.
CAUTION
This symbol shows that a service personnel should be handling this equipment with reference to the Installation Manual.
CAUTION
This symbol shows that information is available such as the Operating Manual or Installation Manual.
WARNING
The appliance contains no user-serviceable parts. Always
consult authorized service personnel for repairing, installation,
and relocation of this product.
Improper installation or handling will cause leakage, electric
shock, or re.
In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the electrical
breaker or disconnecting the power plug. Then consult
authorized service personnel.
Take care not to damage the power supply cable.
If it is damaged, it should only be replaced by authorized
service personnel.
In the event of refrigerant leakage, be sure to keep away
from re or any ammables, and consult authorized service
personnel.
If you see lightning or hear thunder, there might be a lightning
strike.
To prevent electric shock hazard, turn off the air conditioner
by using the remote controller, and do not touch the unit or
the power plug during thunderstorm.
The appliance shall be stored in a room without continuously
operating ignition sources (for example: open ames, an
operating gas appliance or an operating electric heater).
The appliance shall be stored in a well-ventilated area.
Be aware that refrigerants may not contain an odour.
The appliance shall be stored so as to prevent mechanical
damage from occurring.
Disposing of the product shall be done properly, in
compliance with national or regional regulations.
During transportation or relocation of the indoor unit, pipes
shall be covered with the wall hook bracket for protection.
Do not move the appliance by holding the indoor unit pipes.
(The stress applied to the pipe joints may cause the
ammable gas to leak during operation).
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of
the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play
with the appliance.
(continued)
Contents
Safety Precautions .......................................................... En-1
Indoor Unit Overview and Operations ............................. En-3
Remote Controller Overview and Operations ..................En-4
Timer Operation...............................................................En-6
Human Sensor (Energy Saving) ......................................En-8
Demand Response and Indoor Unit Operation ............... En-8
General Informations on Operation .................................En-9
Care and Cleaning.........................................................En-10
Troubleshooting .............................................................En-12
R32
REFRIGERANT
This Air Conditioner contains and
operates with refrigerant R32.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance or service of this product.
9333003016_OM_EN.indd 19333003016_OM_EN.indd 1 7/1/2013 10:39:49 AM7/1/2013 10:39:49 AM

Other manuals for Fujitsu ASTG12KMCA

Questions and Answers:

Fujitsu ASTG12KMCA Specifications

General IconGeneral
TypeSplit System Air Conditioner
Cooling Capacity3.4 kW
Heating Capacity4.0 kW
Seasonal Energy Efficiency Ratio (SEER)6.1
Energy Efficiency Class CoolingA++
Energy Efficiency Class HeatingA+
Power Supply220-240 V, 50 Hz
RefrigerantR32
Weight (Indoor Unit)9.5 kg
Weight (Outdoor Unit)23 kg
Noise Level (Indoor)22 dB(A)

Summary

Safety Precautions

WARNING & CAUTION Categories

Defines warning levels for death, serious injury, property damage, or injury.

General Operational Safety

Covers user-serviceable parts, handling leaks, electrical hazards, and refrigerant safety.

Environmental & Handling Cautions

Cautions regarding ignition sources, ventilation, mechanical damage, and user capabilities.

Prohibited Actions and Environment

Details prohibited actions and environmental conditions to avoid during use.

Usage and Handling Cautions

Provides cautions on ventilation, equipment placement, power, airflow, and unit handling.

Indoor Unit Overview and Operations

Human Sensor and Energy Saving

Explains the Human Sensor function for energy saving and temperature control.

Remote Controller Overview and Operations

Remote Controller Safety & Handling

Highlights safety precautions for handling, battery use, and potential obstacles.

Energy Saving Sensor Activation

Describes the SENSOR button for activating the energy saving program.

Timer Operation

WEEKLY Timer Setup

Details on setting up weekly timer programs for scheduling operations.

Human Sensor (Energy Saving)

Troubleshooting

Critical Warning & Immediate Actions

Critical warnings and immediate actions for severe issues like smoke or burning smells.

Diagnostic Checklist

A guide to diagnose common issues like no operation or poor performance.

Related product manuals