EasyManua.ls Logo

Fujitsu ASTG18KMCB - User Manual

Fujitsu ASTG18KMCB
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
En-1
AIR CONDITIONER
Wall Mounted Type
ASTG18KMCB
ASTG22KMCB
ASTG24KMCB
OPERATING MANUAL
Before using this product, read these instructions thoroughly and keep this manual for future reference.
Safety Precautions
To prevent personal injury, or property damage, read this section carefully before you use this product, and be sure to comply with the following
safety precautions.
Incorrect operation due to failure to follow the instructions may cause harm or damage, the seriousness of which is classi ed as follows:
WARNING CAUTION
This mark warns of death or serious injury. This mark warns of injury or damage to property.
This mark denotes an action that is PROHIBITED.
This mark denotes an action that is COMPULSORY.
Explanation of symbols displayed on the indoor unit or outdoor unit.
WARNING
This symbol shows that this appliance uses a ammable refrigerant. If the refrigerant is leaked and exposure to an external
ignition source, there is a risk of re.
CAUTION
This symbol shows that the Operation Manual should be read carefully.
CAUTION
This symbol shows that a service personnel should be handling this equipment with reference to the Installation Manual.
CAUTION
This symbol shows that information is available such as the Operating Manual or Installation Manual.
WARNING
The appliance contains no user-serviceable parts. Always
consult authorized service personnel for repairing, installation,
and relocation of this product.
Improper installation or handling will cause leakage, electric
shock, or re.
In the event of a malfunction such as burning smell,
immediately stop operation of the air conditioner, and
disconnect all the power supply by turning off the electrical
breaker or disconnecting the power plug. Then consult
authorized service personnel.
Take care not to damage the power supply cable.
If it is damaged, it should only be replaced by authorized
service personnel.
In the event of refrigerant leakage, be sure to keep away
from re or any ammables, and consult authorized service
personnel.
In the event of a thunder storm or any prior sign of a lightning
strike, turn off the air conditioner via the remote controller,
and refrain from touching the product or the power source to
prevent any electrical hazards.
The appliance shall be stored in a room without continuously
operating ignition sources (for example: open ames, an
operating gas appliance or an operating electric heater).
The appliance shall be stored in a well-ventilated area.
Be aware that refrigerants may not contain an odour.
The appliance shall be stored so as to prevent mechanical
damage from occurring.
Disposing of the product shall be done properly, in
compliance with national or regional regulations.
During transportation or relocation of the indoor unit, pipes
shall be covered with the wall hook bracket for protection.
Do not move the appliance by holding the indoor unit pipes.
(The stress applied to the pipe joints may cause the
ammable gas to leak during operation).
This appliance is not intended for use by persons (including
children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they
have been given supervision or instruction concerning use of
the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play
with the appliance.
(continued)
Contents
Safety Precautions ............................................................... 1
Indoor Unit Overview and Operations .................................. 3
Remote Controller Overview and Operations ....................... 4
Timer Operation.................................................................... 6
Human Sensor (Energy Saving) ........................................... 8
Demand Response and Indoor Unit Operation .................... 8
General Information on Operation ........................................ 9
Care and Cleaning.............................................................. 10
Troubleshooting .................................................................. 12
R32
REFRIGERANT
This Air Conditioner contains and
operates with refrigerant R32.
THIS PRODUCT MUST ONLY BE INSTALLED OR SERVICED
BY QUALIFIED PERSONNEL.
Refer to Commonwealth, State, Territory and local legislation,
regulations, codes, installation & operation manuals, before
the installation, maintenance or service of this product.
PART No. 9320455040-02
9320455040-02_OM_EN.indd 19320455040-02_OM_EN.indd 1 12/1/2017 11:01:07 AM12/1/2017 11:01:07 AM

Questions and Answers

Overview

This document is an operating manual for a Fujitsu wall-mounted air conditioner, specifically models ASTG18KMCB, ASTG22KMCB, and ASTG24KMCB. It provides comprehensive information on safety, operation, maintenance, and troubleshooting.

Function Description:

The Fujitsu wall-mounted air conditioner is designed to provide cooling, heating, and dehumidification for indoor spaces. It utilizes R32 refrigerant, a flammable refrigerant, and is equipped with various features to enhance comfort, energy efficiency, and user convenience. Key functions include:

  • Cooling/Heating/Dry/Fan Modes: Allows users to select the desired operating mode for temperature control and air circulation.
  • POWERFUL Operation: Activates maximum power and strong airflow for rapid cooling or heating.
  • 10 °C HEAT Operation: Maintains a room temperature of 10 °C to prevent it from dropping too low, useful for unoccupied spaces in cold climates.
  • Human Sensor (Energy Saving Program): Detects human presence to automatically adjust temperature settings, promoting energy efficiency.
  • Demand Response: Compatible with electricity supplier demand response programs, allowing the unit to operate in reduced capacity modes (DR mode 1, 2, 3) to save energy during peak demand.
  • Timer Operations: Includes ON timer, OFF timer, Program timer (combined ON/OFF), WEEKLY timer (up to 4 programs per day, 28 per week), and SLEEP timer for scheduled operation and comfortable sleep.
  • Airflow Direction Control: Independent control of vertical and horizontal airflow direction louvers for customized air distribution.
  • Air Cleaning Filters: Purifies and deodorizes the air, providing fresh airflow. Includes Apple-catechin filters and Ion deodorization filters.
  • Auto-restart Function: Automatically resumes previous operation settings after a power interruption.
  • Automatic Defrosting Operation: Prevents frost buildup on the outdoor unit during heating in low temperatures and high humidity, maintaining performance.

Important Technical Specifications:

  • Refrigerant: R32 (flammable refrigerant). Installation and servicing must be performed by qualified personnel.
  • Temperature Setting Range:
    • AUTO/COOL/DRY mode: 18.0-30.0 °C
    • HEAT mode: 16.0-30.0 °C (10 °C HEAT operation maintains 10 °C)
  • Permissible Temperature and Humidity Range:
    • COOL/DRY: Indoor temperature 18-32 °C, Indoor humidity below approximately 80%.
    • HEAT: Indoor temperature 16-30 °C.
  • Remote Controller Operating Range: Approximately 7 meters.
  • Air Cleaning Filters:
    • Apple-catechin filter: UTR-FA16 (disposable, replace every 3 months under normal use).
    • Ion deodorization filter: UTR-FA16-2 (clean every 3 months, replace every 3 years under normal use).
  • Power Supply: Not explicitly stated but implied to be standard residential/commercial electrical supply.
  • Wireless LAN Control: Built-in adapter for control via mobile app (requires separate setting manual).

Usage Features:

  • Remote Controller: A comprehensive remote controller allows for selection of modes, temperature, fan speed (Auto, High, Med, Low, Quiet), swing operation (Up/down, Left/right, Up/down/left/right, Stop swing), and various timer settings. It also features a signal transmit indicator and a display for current settings.
  • Custom Code Setting: Allows for setting a custom code on the remote controller to prevent interference when multiple air conditioners are installed in the same room (4 selections possible: A, B, C, D).
  • MANUAL AUTO Button: Located on the indoor unit, this button allows for basic operation (Stop, AUTO, Forced cooling) in case the remote controller is lost or malfunctions. It also serves to reset the filter indicator.
  • Human Sensor (ENERGY SAVING PROGRAM): Activated via the SENSOR button on the remote controller. Automatically adjusts temperature when no one is detected in the room for approximately 20 minutes (increases 2°C in COOL/DRY, decreases 4°C in HEAT).
  • Demand Response (DR) Modes: When activated by the electricity supplier, the unit automatically switches to a reduced capacity mode (DR mode 1: compressor off; DR mode 2: 50% energy consumption; DR mode 3: 75% energy consumption). The OPERATION indicator blinks to signify DR mode.
  • Timer Functions:
    • ON/OFF Timer: Sets specific ON or OFF times.
    • Program Timer: Combines ON-OFF or OFF-ON timers.
    • SLEEP Timer: Gradually adjusts temperature for comfortable sleep, then turns off the unit.
    • WEEKLY Timer: Allows scheduling up to 4 ON/OFF programs per day for each day of the week, with customizable temperature settings for ON programs.
  • Wired Remote Controller (Option): An optional wired remote controller can be used, offering additional functions like a temperature setback timer. It can be used in conjunction with the wireless remote controller, though some wireless functions may be restricted.
  • Indicator Lights:
    • OPERATION indicator (green): Lights during normal operation, blinks during Automatic Defrosting and Demand Response.
    • ECONOMY indicator (green): Lights during ECONOMY operation and 10 °C HEAT operation, blinks when air filter cleaning is due.
    • TIMER indicator (orange): Lights during TIMER operation, blinks slowly for timer setting errors.

Maintenance Features:

  • Air Filter Cleaning: Regular cleaning of air filters (every 2 weeks under normal use) is crucial for maintaining product performance and preventing airflow reduction or increased operating noise. The manual provides detailed steps for removing, cleaning (with vacuum or washing with neutral detergent and warm water), drying, and reinstalling the intake grille and air filters.
  • Air Cleaning Filter Replacement/Maintenance:
    • Apple-catechin filter: Disposable, replace every 3 months.
    • Ion deodorization filter: Clean every 3 months by flushing with high-pressure hot water and gentle washing with neutral detergent; replace every 3 years.
  • Filter Indicator Reset: The ECONOMY indicator lamp flashes (3 times, at 21-second intervals) when it's time to clean the air filters. After cleaning, reset the indicator by pressing the "MANUAL AUTO" button on the indoor unit for 3 seconds or less.
  • Extended Non-Use: If the unit has been shut down for a month or more, perform FAN operation for half a day to dry internal parts thoroughly before normal operation.
  • Additional Inspection: After long periods of use, accumulated dust may reduce performance, and a product inspection by authorized service personnel is recommended.
  • Troubleshooting Guide: Provides a list of common symptoms, their causes (normal functions or characteristics), and diagnostic checks to perform before calling for service. This includes checks for power supply, timer operation, dirty filters, blocked grilles, and remote controller battery status.
  • Safety Precautions: Emphasizes the importance of disconnecting power before cleaning, avoiding contact with aluminum fins, not using liquid insecticides or hair sprays on the unit, and not standing on unstable surfaces during maintenance.

Fujitsu ASTG18KMCB Specifications

General IconGeneral
BrandFujitsu
ModelASTG18KMCB
CategoryAir Conditioner
LanguageEnglish

Related product manuals