Trouble shooting 18
OUTDOOR UNIT Error Method:
Indicate or Display:
Detective Actuators:
Detective details:
Forecast of Cause :
Check Point 2 :
Check Point 3 :
4.77
77°F
5.98
68°C
7.56Resistance Value (k )
59°F14°FTemperature(°F)
DC
3.84
86°F
Heat Ex. Thermistor Error
Outdoor Unit Main PCB Circuit
Heat Exchanger Temperature Thermistor
When Heat Exchanger Temperature Thermistor open or short-circuit is
detected at power ON or while running the compressor.
1. Connector connection failure 2.Thermistor failure 3. Main PCB failure
Check Point 1 : Check connection of Connector
Check if connector is removed.
Check erroneous connection.
Check if thermistor cable is open.
>>Upon correcting the removed connector or mis-wiring, reset the power.
Check Point 2 : Remove connector and check Thermistor resistance value
Thermistor Characteristics (Approx. value)
If Thermistor is either open or shorted, replace it and reset the power.
Check Point 3 : Check voltage of Main PCB (DC5.0V)
Make sure circuit diagram of outdoor unit and check terminal voltage at Thermistor (DC5.0V)
If the voltage does not appear, replace Main PCB.
02-22
Refer to error code table.
THERMISTOR
(DISCHARGE)
BROWN
CN25 CN26 CN23 CN22 CN21
1 2
THERMISTOR
(COMPRESSOR)
BROWN
1 2
1 2 1 2 1 2
BLUE
BLACK
BLACK
THERMISTOR
(HEAT SINK)
THERMISTOR
(OUTDOOR)
THERMISTOR
(PIPE)
OK
OK
23°F 32°F 41°F 50°F
27.8 21.0 16.1 12.4 9.63