EasyManua.ls Logo

Fujitsu ASU15RLS2 - Service Manual

Fujitsu ASU15RLS2
25 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
SPLIT TYPE
ROOM AIR CONDITIONER
WALL MOUNTED TYPE
CONTENTS
SPECIFICATIONS. . . . . . . . . . . . . . . . . . .
1
DIMENSIONS . . . . . . . . . . . . . . . . . . . . . .
2
REFRIGERANT SYSTEM DIAGRAM. . . .
3
CIRCUIT DIAGRAM . . . . . . . . . . . . . . . . .
4
ERROR DETECTION . . . . . . . . . . . . . . .
5
INDOOR PCB CIRCUIT DIAGRAM . . . . .
9
OUTDOOR PCB CIRCUIT DIAGRAM . . .
13
PARTS (INDOOR UNIT) . . . . . . . . . . . . .
15
PARTS (OUTDOOR UNIT) . . . . . . . . . . .
20
23
ACCESSORIES . . . . . . . . . . . . . . . . . . .
Indoor unit Outdoor unit
ASU15RLS2 AOU15RLS2H

Other manuals for Fujitsu ASU15RLS2

Questions and Answers

  • M
    Michael HendersonAug 13, 2025
    What to do if my Fujitsu Air Conditioner remote is not working due to a communication error?
    • R
      robertbarronAug 13, 2025
      If you're experiencing a Wired Remote Controller Communication Error with your Fujitsu Air Conditioner, check the voltage. If it's DC12V, the remote control has failed and should be replaced. If it's DC 0V, the Controller PCB has failed and should be replaced after rechecking the remote control.
  • P
    pkeithAug 17, 2025
    What to do if my Fujitsu Air Conditioner has a drainage error?
    • C
      cynthia07Aug 17, 2025
      If your Fujitsu Air Conditioner is experiencing drainage issues, start by inspecting the float switch for proper operation using a meter to check its on/off switching. If the float switch is defective, replace it. Also, examine the drain hose for any clogs and clear them if necessary. If these steps don't resolve the issue, consider replacing the controller PCB.
  • V
    velazquezkaylaAug 20, 2025
    How to fix a Fujitsu ASU15RLS2 Air Conditioner indoor unit fan motor error?
    • J
      Jeanette GutierrezAug 20, 2025
      If you're encountering an indoor unit fan motor error with your Fujitsu Air Conditioner, check first the fan and bearing. If either is damaged, replace them. If the motor itself is faulty, replace the indoor unit fan motor. If these steps do not resolve the issue, replace the controller PCB.
  • D
    Desiree NewtonAug 25, 2025
    What to do if my Fujitsu ASU15RLS2 shows an indoor room thermistor error?
    • J
      Joseph WuAug 25, 2025
      If your Fujitsu Air Conditioner displays an indoor room thermistor error, begin by checking the connector to ensure it is securely attached and properly connected, and verify that the thermistor cable is not open. If the thermistor is either open or shorted, replace it and then reset the power.
  • J
    Jason TaylorAug 28, 2025
    How to troubleshoot an Indoor Unit Model Information Error on my Fujitsu ASU15RLS2 Air Conditioner?
    • A
      Andrew MorrisAug 28, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Model Information Error, check for external causes such as noise and ensure the ground connection is properly connected. Also, inspect all connectors for looseness or incorrect wiring, and check the PCB for any shorts or corrosion. If the problem persists, consider replacing the Controller PCB.
  • W
    whitekylieSep 1, 2025
    What does an Indoor Unit Capacity Error mean on my Fujitsu ASU15RLS2?
    • A
      Allison SmithSep 1, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Capacity Error, first verify the total capacity of the connected indoor units. If an abnormal condition is found, correct it by referring to the Installation Manual or Design & Technical Manual. If the problem persists, replace the Main PCB of the Outdoor unit.
  • A
    Ariel CharlesSep 4, 2025
    How to fix a Serial Communication Error (Serial Reverse Transfer Error) on a Fujitsu ASU15RLS2?
    • D
      Diana PageSep 4, 2025
      If your Fujitsu Air Conditioner displays a Serial Communication Error (Serial Reverse Transfer Error), check all connection lines between the indoor and outdoor units for any looseness or disconnections, referring to the Installation Manual or Data & Technical Manual for correction. Also, check the voltage of the power supply, ensuring it appears at the outdoor unit terminal L1 - L2 within the range of AC187V - 253V. Check that the indicated value swings between AC90V and AC270V at outdoor unit terminal 1 - 3. If the outdoor fan motor, active filter module, or IPM is abnormal, replace the corresponding part. If all parts are normal, replace the Main PCB.
  • T
    Tom ShafferSep 8, 2025
    How to resolve a Damper (Open/Close) simultaneous detection Limit switch error on a Fujitsu ASU15RLS2?
    • K
      kenneth21Sep 8, 2025
      If your Fujitsu Air Conditioner displays a Damper(Open/Close) simultaneous detection Limit switch error, replace the limit switch if it is defective. If the problem persists, replace the Controller PCB.

Summary

Specifications

Electrical Data

Detailed electrical specifications for the unit's performance.

Circuit Diagrams

Indoor Unit Circuit Diagrams

Overview of the indoor unit's electrical circuit.

Outdoor Unit Circuit Diagrams

Overview of the outdoor unit's electrical circuit.

Error Detection

Indoor Unit Error Indicators

Error codes indicated by blinking lamps on the indoor unit.

Wired Remote Control Error Codes

Error codes displayed on the wired remote control.

Outdoor Unit Error Indicators

Outdoor Unit LED Error Codes

Error codes indicated by LED blinking patterns on the outdoor unit.

Fujitsu ASU15RLS2 Specifications

General IconGeneral
BrandFujitsu
ModelASU15RLS2
CategoryAir Conditioner
LanguageEnglish

Related product manuals