AIR CONDITIONER
Multi: 2, 3, 4 rooms type
DESIGN & TECHNICAL MANUAL
INDOOR
AUU7RLF
AUU9RLF
AUU12RLF
AUU18RLF
ARU7RLF
ARU9RLF
ARU12RLF
ARU18RLF ARU24RLF
ASU7RLF1
ASU9RLF1
ASU12RLF1
ASU15RLF1
ASU7RLF*
ASU9RLF*
ASU12RLF*
ASU9RLS2*
ASU12RLS2*
ASU15RLS2*
ASU18RLF
ASU24RLF
AGU9RLF
AGU12RLF
AGU15RLF
*: AOU36RLXFZ1 is not connectable.
OUTDOOR
AOU18RLXFZ
AOU24RLXFZ
AOU36RLXFZ1
DR_MU008EF_07
2018.06.14

Table of Contents

Other manuals for Fujitsu ASU15RLF1

Questions and Answers

  • E
    Ernest MorrisAug 13, 2025
    What to do if my Fujitsu Air Conditioner remote is not working due to a communication error?
    • R
      Robert AdamsAug 13, 2025
      If you're experiencing a Wired Remote Controller Communication Error with your Fujitsu Air Conditioner, check the voltage. If it's DC12V, the remote control has failed and should be replaced. If it's DC 0V, the Controller PCB has failed and should be replaced after rechecking the remote control.
  • K
    Katie GarciaAug 16, 2025
    What to do if my Fujitsu Air Conditioner has a drainage error?
    • K
      kjacksonAug 16, 2025
      If your Fujitsu Air Conditioner is experiencing drainage issues, start by inspecting the float switch for proper operation using a meter to check its on/off switching. If the float switch is defective, replace it. Also, examine the drain hose for any clogs and clear them if necessary. If these steps don't resolve the issue, consider replacing the controller PCB.
  • M
    Meredith BenjaminAug 20, 2025
    How to fix a Fujitsu ASU15RLF1 Air Conditioner indoor unit fan motor error?
    • M
      Mrs. Ashley GarrisonAug 20, 2025
      If you're encountering an indoor unit fan motor error with your Fujitsu Air Conditioner, check first the fan and bearing. If either is damaged, replace them. If the motor itself is faulty, replace the indoor unit fan motor. If these steps do not resolve the issue, replace the controller PCB.
  • A
    Alexis RangelAug 25, 2025
    What to do if my Fujitsu ASU15RLF1 shows an indoor room thermistor error?
    • K
      Karen LloydAug 25, 2025
      If your Fujitsu Air Conditioner displays an indoor room thermistor error, begin by checking the connector to ensure it is securely attached and properly connected, and verify that the thermistor cable is not open. If the thermistor is either open or shorted, replace it and then reset the power.
  • M
    Mr. Andrew OlsonAug 28, 2025
    How to troubleshoot an Indoor Unit Model Information Error on my Fujitsu Air Conditioner?
    • V
      Victoria Tran DDSAug 28, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Model Information Error, check for external causes such as noise and ensure the ground connection is properly connected. Also, inspect all connectors for looseness or incorrect wiring, and check the PCB for any shorts or corrosion. If the problem persists, consider replacing the Controller PCB.
  • S
    Stacy TaylorSep 1, 2025
    What does an Indoor Unit Capacity Error mean on my Fujitsu Air Conditioner?
    • J
      Jose LopezSep 1, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Capacity Error, first verify the total capacity of the connected indoor units. If an abnormal condition is found, correct it by referring to the Installation Manual or Design & Technical Manual. If the problem persists, replace the Main PCB of the Outdoor unit.
  • K
    Kristy OlsonSep 4, 2025
    How to fix a Serial Communication Error (Serial Reverse Transfer Error) on a Fujitsu Air Conditioner?
    • S
      stephensmargaretSep 4, 2025
      If your Fujitsu Air Conditioner displays a Serial Communication Error (Serial Reverse Transfer Error), check all connection lines between the indoor and outdoor units for any looseness or disconnections, referring to the Installation Manual or Data & Technical Manual for correction. Also, check the voltage of the power supply, ensuring it appears at the outdoor unit terminal L1 - L2 within the range of AC187V - 253V. Check that the indicated value swings between AC90V and AC270V at outdoor unit terminal 1 - 3. If the outdoor fan motor, active filter module, or IPM is abnormal, replace the corresponding part. If all parts are normal, replace the Main PCB.
  • A
    Alison RogersSep 8, 2025
    How to resolve a Damper (Open/Close) simultaneous detection Limit switch error on a Fujitsu ASU15RLF1?
    • S
      Sean BairdSep 8, 2025
      If your Fujitsu Air Conditioner displays a Damper(Open/Close) simultaneous detection Limit switch error, replace the limit switch if it is defective. If the problem persists, replace the Controller PCB.

Summary

Indoor Unit Specifications

Compact Cassette Type Specifications

Detailed technical specifications for compact cassette indoor units.

Slim Duct Type Specifications

Detailed technical specifications for slim duct indoor units.

Wall Mounted Type Specifications

Detailed technical specifications for wall mounted indoor units.

Floor Type Specifications

Detailed technical specifications for floor type indoor units.

Indoor Unit Dimensions

Indoor Unit Wiring Diagrams

Compact Cassette Type Wiring

Electrical wiring diagrams for compact cassette type indoor units.

Slim Duct Type Wiring

Electrical wiring diagrams for slim duct type indoor units.

Wall Mounted Type Wiring

Electrical wiring diagrams for wall mounted type indoor units.

Floor Type Wiring

Electrical wiring diagrams for floor type indoor units.

Fan Performance

Indoor Unit Airflow Rates

Indoor Unit Noise Level Curves

Indoor Unit Electrical Characteristics

Indoor Unit Safety Devices

Indoor Unit External Input and Output

External Input Functions

Details on connecting external devices for indoor unit control.

External Output Functions

Details on external outputs for indoor unit status and control signals.

Remote Controller Overview

Wireless Remote Controller (UTY-LNHUM;AR-RAH1 U)

Overview of UTY-LNHUM/AR-RAH1U wireless remote controller buttons and functions.

Wireless Remote Controller (AR-RED1 U;AR-REG1 U)

Overview of AR-RED1U/AR-REG1U wireless remote controller buttons and functions.

Wired Remote Controller (UTY-RNNUM)

Overview of UTY-RNNUM wired remote controller, including buttons and system diagrams.

Simple Remote Controller (UTY-RSNUM)

Overview of UTY-RSNUM simple remote controller and its function settings.

Indoor Unit Function Settings

Indoor Unit Installation Precautions

Places Prohibited for Indoor Unit Use

Guidelines on unsuitable installation locations for indoor units to ensure safety.

Points to Remember During Indoor Unit Installation

Key considerations and environmental factors for proper indoor unit installation.

Outdoor Unit (2 Rooms Type) Specifications

AOU18 RLXFZ Specifications

Technical specifications for the AOU18RLXFZ outdoor unit (2 Rooms Type).

Outdoor Unit (2 Rooms Type) Dimensions

Outdoor Unit (2 Rooms Type) Installation Space

Outdoor Unit (2 Rooms Type) Refrigerant Circuit

Outdoor Unit (2 Rooms Type) Wiring Diagram

AOU18 RLXFZ Wiring Diagram

Electrical wiring diagram for the AOU18RLXFZ outdoor unit.

Outdoor Unit (2 Rooms Type) Capacity Table

Outdoor Unit (2 Rooms Type) Cooling Capacity

Outdoor Unit (2 Rooms Type) Heating Capacity

Outdoor Unit (2 Rooms Type) Capacity Compensation

Outdoor Unit (2 Rooms Type) Electrical Characteristics

Outdoor Unit (2 Rooms Type) Safety Devices

Outdoor Unit (2 Rooms Type) Installation Precautions

Outdoor Unit (3 Rooms Type) Specifications

AOU24 RLXFZ Specifications

Technical specifications for the AOU24RLXFZ outdoor unit (3 Rooms Type).

Outdoor Unit (3 Rooms Type) Dimensions

Outdoor Unit (3 Rooms Type) Installation Space

Outdoor Unit (3 Rooms Type) Refrigerant Circuit

Outdoor Unit (3 Rooms Type) Wiring Diagram

AOU24 RLXFZ Wiring Diagram

Electrical wiring diagram for the AOU24RLXFZ outdoor unit.

Outdoor Unit (3 Rooms Type) Capacity Table

Outdoor Unit (3 Rooms Type) Cooling Capacity

Outdoor Unit (3 Rooms Type) Heating Capacity

Outdoor Unit (3 Rooms Type) Capacity Compensation

Outdoor Unit (3 Rooms Type) Electrical Characteristics

Outdoor Unit (3 Rooms Type) Safety Devices

Outdoor Unit (3 Rooms Type) Installation Precautions

Points to Remember During Outdoor Unit Installation

Important considerations for installing outdoor units, including environmental factors.

Outdoor Unit (4 Rooms Type) Specifications

AOU36 RLXFZ1 Specifications

Technical specifications for the AOU36RLXFZ1 outdoor unit (4 Rooms Type).

Outdoor Unit (4 Rooms Type) Dimensions

Outdoor Unit (4 Rooms Type) Installation Space

Outdoor Unit (4 Rooms Type) Refrigerant Circuit

Outdoor Unit (4 Rooms Type) Wiring Diagram

AOU36 RLXFZ1 Wiring Diagram

Electrical wiring diagram for the AOU36RLXFZ1 outdoor unit.

Outdoor Unit (4 Rooms Type) Capacity Table

Outdoor Unit (4 Rooms Type) Cooling Capacity

Outdoor Unit (4 Rooms Type) Heating Capacity

Outdoor Unit (4 Rooms Type) Capacity Compensation

Outdoor Unit (4 Rooms Type) Electrical Characteristics

Outdoor Unit (4 Rooms Type) Safety Devices

Outdoor Unit Installation Precautions

Places Prohibited for Outdoor Unit Use

Precautions regarding installation locations to avoid hazards for outdoor units.

Fujitsu ASU15RLF1 Specifications

General IconGeneral
TypeSplit System
Heating Capacity18, 000 BTU/h
Voltage208/230 V
RefrigerantR410A
Weight (Indoor Unit)20 lbs
Cooling Capacity15, 000 BTU/h
Power Supply1 Phase, 60Hz
Noise Level (Indoor Unit)43 dB(A) (High)