01-02
START
Room temp.
Ts+4°F(+2°C)?
COOLING (AUTO:DRY)
OPERATION
HEATING OPERATION
YES
YES
NO
NO
NO
AUTO CHANGEOVER operation flow chart
TS : Setting temperature
Room temp.
Ts -4°F(-2°C)?
Thermostat remains
in OFF state for 6 minutes or
longer?
System stops
or operation command other than
auto changeover operation?
NO
Thermostat remains
in OFF state for 6 minutes or
longer?
System stops
or operation command other than
auto changeover operation?
Middle zone
NO
Operation mode
of outdoor unit : Cooling or Dry?
YES
NO
Operation mode
of outdoor unit : Heating?
YES
NO
YES
Outdoor temperature
77
°F(25°C)?
NO
YES
YES
NO
YES
YES
When Heating was selected at , the same operation as HEATING OPERATION of page
01-02 is performed.
When the compressor was stopped for 6 consecutive minutes by the temperature control function
after the Cooling(Auto:Dry) or Heating mode was selected at above, operation is switched
to Monitoring and the operation mode is selected again.
3
1
4
1

Other manuals for Fujitsu ASU24RLF

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASU24RLF and is the answer not in the manual?

Fujitsu ASU24RLF Specifications

General IconGeneral
BrandFujitsu
ModelASU24RLF
CategoryAir Conditioner
LanguageEnglish

Related product manuals