Trouble shooting 6
INDOOR UNIT
OUTDOOR UNIT Error Method:
Indicate or Display:
Detective Actuators:
Detective details:
Forecast of Cause :
Check Point 2 :
Check Point 3 :
OKOK
OKOK
12.620.726.935.246.662.3115Resistance Value (k ) 16.1
Temperature
3.45 2.36 1.65Resistance Value (k ) 5.187.97
Temperature
Outdoor Temperature Sensor Error
Outdoor Unit Main PCB Circuit
Outdoor Temperature Thermistor
When Outdoor Temperature Thermistor open or short-circuit is
detected at power ON or while running the compressor.
1. Connector connection failure 2.Thermistor failure 3. Main PCB failure
Check Point 1 : Check connection of Connector
Check if connector is removed.
Check erroneous connection.
Check if thermistor cable is open.
>>Upon correcting the removed connector or mis-wiring, reset the power.
Check Point 2 : Remove connector and check Thermistor resistance value
Thermistor Characteristics (Approx. value)
If Thermistor is either open or shorted, replace it and reset the power.
Check Point 3 : Check voltage of Main PCB (DC5.0V)
Make sure circuit diagram of outdoor unit and check terminal voltage at Thermistor (DC5.0V)
If the voltage does not appear, replace Main PCB.
06-10
Outdoor Unit : LED 0.1sec ON/ 0.1sec OFF
Indoor Unit : Operation LED : 3 times, Timer LED : 4 times
ERROR CODE : [E : 0A]
THERMISTOR
(PIPE)
THERMISTOR
(DISCHARGE)
THERMISTOR
(OUTDOOR)
BLACK
CN62 CN61
3 2 1 4 3 2 1
BROWN
BLACK
3 2 1 4 3 2 1
23°F
(-5°C)
14°F
(-10°C)
158°F
(70°C)
140°F
(60°C)
86°F
(
30°C)
68°F
(20°C)
59°F
(15°C)
50°F
(10°C)
41°F
(5°C)
32°F
(0°C)
122°F
(
50°C)
104°F
(
40°C)
-4°F