02 - 08
)
-
OUTDOOR UNIT
AOU36R
OUTDOOR UNIT
AOU36R
This table is created using the maximum capacity.
COEFFICIENT OF COMPENSATION FOR HEIGHT DIFFERENCE
INDOOR UNIT 18000BTU (AOU36R)
Height difference H
5m 7.5m 10m 15m 20m 25m
16ft. 25ft. 33ft. 49ft. 66ft. 82ft.
15m 49ft. - - -
0.992 0.985 0.978
10m 33ft. - -
0.998 0.992 0.985 0.978
7.5m 25ft. -
1.000 0.998 0.992 0.985 0.978
5m 16ft.
1.002 1.000 0.998 0.992 0.985 0.978
0m 0ft. 1.002 1.000 0.998 0.992 0.985 0.978
-5m -16ft.
0.994 0.992 0.990 0.984 0.977 0.970
-7.5m -25ft. -
0.988 0.986 0.980 0.973 0.966
-10m -33ft. - -
0.982 0.976 0.969 0.962
-15m -49ft. - - -
0.968 0.961 0.954
COOLING
Height difference H
1
2
Pipe length
5m 7.5m 10m 15m 20m 25m
16ft. 25ft. 33ft. 49ft. 66ft. 82ft.
15m 49ft. - - -
0.935 0.903 0.887
10m 33ft. - -
0.981 0.940 0.908 0.892
7.5m 25ft. -
0.993 0.983 0.943 0.910 0.894
5m 16ft.
0.995 0.995 0.986 0.945 0.912 0.896
0m 0ft. 1.000 1.000 0.990 0.950 0.917 0.901
-5m -16ft.
1.000 1.000 0.990 0.950 0.917 0.901
-7.5m -25ft. -
1.000 0.990 0.950 0.917 0.901
-10m -33ft. - -
0.990 0.950 0.917 0.901
-15m -49ft. - - -
0.950 0.917 0.901
HEATING
Height difference H
1
2
Pipe length
Indoor unit
Connection pipe
H
Outdoor unit
Indoor unit is upper than outdoor unit.
1
Indoor unit
Connection pipe
H
Outdoor unit
Indoor unit is under than outdoor unit.
2
Indoor unit is under
than outdoor unit
Indoor unit is upper
than outdoor unit
Indoor unit is under
than outdoor unit
Indoor unit is upper
than outdoor unit