3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢ Fan speed
Indoor fan speed is defined as below.
Operation mode Fan mode
Speed (rpm)
ASUH18LPAS ASUH24LPAS
Heating
POWERFUL 1,310 1,490
HIGH 1,210 1,390
MED+ 1,130 1,320
MED 1,020 1,210
LOW 860 960
QUIET 700 810
Cool air prevention 580 680
S-LOW 540 540
Cooling/Fan
POWERFUL 1,360 1,590
HIGH 1,260 1,490
MED 1,140 1,140
LOW 960 960
QUIET 680 810
Soft quiet
580*
1
680*
1
S-LOW
540*
2
540*
2
Dry
X zone: 680
J zone: 640
X zone: 810
J zone: 760
*1: Fan mode only
*2: Cooling mode only
¢ Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.
3-1. Indoor fan control
- (04-8) - 3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS