Check point 9-1. Check function setting
Change setting of function 48 (Room temperature sensor switching) to 01.
NOTE: For details of function setting number 48, refer to "Function settings " in Chapter 5. FIELD
WORKING on page 05-1.
↓
Check point 9-2. Check the effects of function setting change
Did this function setting improve temperature control?
→ If the space is still too cool, go to "Check point 10".
↓
End
Check point 12. Check function setting
Using the table on the right adjust temperature correction by changing function setting 35. (Room
Temperature control for wired remote controller sensor)
NOTE: For details of function setting number 35, refer to "Function settings " in Chapter 5. FIELD
WORKING on page 05-1.
↓
End
3-8. Too cool - (03-48) - 3. Troubleshooting without error code
TROUBLESHOOTING
TROUBLESHOOTING