EasyManuals Logo

Fujitsu ASUH36LPAS User Manual

Fujitsu ASUH36LPAS
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
8-1. External input
With using external input function, some functions on this product can be controlled from an external
device.
“Operation/Stop” mode or "Forced stop" mode can be selected with function setting of indoor unit.
A twisted pair cable (22AWG) should be used. Maximum length of cable is 492 ft (150 m).
The wire connection should be separate from the power cable line.
¢
Indoor unit
Indoor unit functions such as Operation/Stop can be done by using indoor unit connectors.
1
2
3

Connector
(CN46)
PCB
Connected unit
*1: The switch can be used on the following condition: DC 12 V to 24 V, 1 mA to 15 mA.
- 15 -
8-1. External input
8. External input and output
WALL MOUNTED
ASUH30-36LPAS
WALL MOUNTED
ASUH30-36LPAS

Table of Contents

Other manuals for Fujitsu ASUH36LPAS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASUH36LPAS and is the answer not in the manual?

Fujitsu ASUH36LPAS Specifications

General IconGeneral
BrandFujitsu
ModelASUH36LPAS
CategoryAir Conditioner
LanguageEnglish

Related product manuals