EasyManua.ls Logo

Fujitsu ASYA07LCC - Page 69

Fujitsu ASYA07LCC
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ASYA09LCC Capacity/Input data (1/2)
< Capacity >
<Input>
*Defrosting operation is performed when temperature is less than 5.5 degrees C.
Frost appears on an outdoor unit heat exchanger at 5.5 or less degrees C.
*Solid line:Integral capacity/Input containing the defrosting cycle.
*Dotted line:Capacity/Input which does not contain the defrosting cycle.
Heating
40%
50%
60%
70%
80%
90%
100%
110%
120%
130%
140%
150%
160%
170%
180%
-15 -10 -5 0 5 10 15 20 25
Capacity(%)
70%
80%
90%
100%
110%
120%
130%
140%
150%
160%
170%
180%
190%
200%
210%
220%
-15 -10 -5 0 5 10 15 20 25
Input(%)
Rated
operation
24
24
Maximum
operation
5.5
5.5
Rated
operation
Maximum
operation
Without Frost
Without Frost
With Frost
Without Frost
With Frost
Without Frost
IndoorDB:20 C
Outdoor DB( C)
Outdoor DB( C)
IndoorDB:20 C
08-09

Other manuals for Fujitsu ASYA07LCC

Related product manuals